[Storage All Restore]
Overview
Select [Storage All Backup] to back up data in the Auto Inspection Unit UK-301 HDD to an external storage device, and restore the data to the Auto Inspection Unit UK-301 HDD.
A: Auto Inspection Unit UK-301
B: Restore
C: External storage
All the following options are required to use this function.
- Intelligent Quality Care Unit IQ-501
- Auto Inspection Unit UK-301
- Video Interface Kit VI-514
- Video Interface Kit VI-515
The following settings are required to use this function.
- Set [Enhanced Security Mode] to [OFF].
- Set [HDD Encryption Set.(UK-301)] to [ON].
- During restore operations, the system automatically enters the power-saving state and hence no other functions can be used. You will not be able to return to the previous screen if an error interrupts the operation after the system enters the power-saving state.
- To cancel the restore operations after they have begun, set the Sub power switch to OFF. Do not set the Main power switch to OFF.
- All the data in the Auto Inspection Unit UK-301 HDD will be overwritten and erased.
- [Storage All Restore] can only be performed when [HDD Encryption Set.(UK-301)] are the same for both back up and restore.
- If the restore fails or is cancelled during processing, the machine reboots. In this case, all data on the HDD will be deleted.
- The data to which the HDD of the Auto Inspection Unit UK-301 was backed up on another machine cannot be stored in the Auto Inspection Unit UK-301 of this system.
- If there are any abnormalities in the data that was backed up to an external storage device, the restore operation will be canceled.
Conditions for restore operations
Ensure that Auto Inspection Unit UK-301 is mounted
Ensure that the external storage media for restoration is securely connected to the USB connection port of Auto Inspection Unit UK-301
Ensure that only one external storage medium for restoration is connected
Ensure that Enhanced Security mode is not set
Setting Procedure
1
Connect the external storage device for restoration to the USB connection port of Auto Inspection Unit UK-301.
2
Press [Start] to display the total size of restored data in the message display area on the screen.
A dialog box is displayed to ask for consent to overwrite and erase all data on the HDD. Press [Yes] to start restoration of all data.
An error message dialog box will be displayed if the restoration operations fail. Press [Close] to retry restoration. If you turn Sub power switch off and back on again without retrying restoration, all the data on the HDD will be erased.
- Be careful that the set all the data on the HDD will be erased if the restore fails or is canceled during processing.
3
After operation is completed, turn the Sub power switch off and back on again.