Use the scanner to correct the IDC sensor and perform gamma correction.
Printer gamma correction is usually done automatically on a regular basis, but changes in the characteristics of the IDC Center may prevent accurate density measurement. Perform [IDC Sensor Adjustment] if the color of output image is not accurate.
The following setting is required to use this function.
This section details the procedure for when neither Intelligent Quality Care Unit IQ-501 or Relay Unit RU-518m are installed.
The chart will be automatically measured if either of Intelligent Quality Care Unit IQ-501 or Relay Unit RU-518m is installed. In such a case, you can stop after step 4.
The contents of the chart to be output may differ.
A chart is output.
Set the triangle mark [2] on the chart [1] to the left and the print side facing down.
Move and touch chart [1] firmly against the vertical direction document size index [3] and horizontal direction document size index [4], and set to Original glass.
If an error occurs, the relevant error code will be displayed.
For details about the error codes, refer to "Error Code" (described after the procedure).
Press [Reset Adj. Data] to display a dialog box. Press [Yes] to reset the colorimetric data held by the system to the ROM adjustment value.
Error Code
Error Code | Error | Supported |
---|---|---|
Error 1 | Crop mark cannot be detected | Place chart at the correct position. |
Error 2 | Chart is placed upside down | Place chart at the correct position. |
Error 3 | Chart pattern cannot be detected | Use the correct chart. |
Error 4 | Cannot adjust | Contact your service representative. |
Error 5 | Not in standard value range | Re-adjust. |
Error 6 | Non-volatile data error | Check that the memory board is mounted correctly. |
Error 7 | Accessed non-specified memory | Contact your service representative. |
Error 8 | Memory related error | Contact your service representative. |
Error 9 | Program error | Contact your service representative. |
Error 10 | Chart is slanting | Use the correct chart. |
Error 11 | Image header information read error | Contact your service representative. |
Error 12 | RGB data error | Check for the correct chart and contact your service representative if problem does not resolve. |
Error 13 | Argument setting error | Contact your service representative. |