Adjust the position to start scanning on the ADF and the image centering in the crosswise direction.
Scanning accuracy is maintained by making regular adjustments.
To make correct adjustments, configure the following setting in advance.
The setting screen is displayed.
[Simplex/Duplex] is selected automatically, so do not change this setting.
If you selected [Restart Timing(Front)] in step 1, load the test chart with its front side facing upward.
If you selected [Restart Timing(Back)] in step 1, load the test chart with its back side facing upward.
Standard value: 0 mm ^ 1.0 mm
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-40~+40 1step = 0.1mm]
[Simplex/Duplex] is selected automatically, so do not change this setting.
If you selected [Centering(Front)] in step 1, load the test chart with its front side facing upward.
If you selected [Centering(Back)] in step 1, load the test chart with its back side facing upward.
Standard value: 0 mm ^ 2.0 mm
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-44~+44 1step = 0.1mm]