Overview
Adjust the scanning start position when scanning the original using the Original glass.
Using this function allows you to check the misalignment between the original and the output paper, and adjust to the correct position.
The following setting is required to use this function.
- Perform [FD-Mag. Adjustment] in [Scan Adjustment].
Setting Procedure
2
Load A3 w or 11 e 17 w paper into any paper tray, and select that paper tray.
3
Place a test chart on the Original glass, and press Start on the Control panel.
A test chart is copied.
4
Check the misalignment by comparing the output paper with the chart.
5
If any adjustments are required, press [Exit PrintMode] to return to the setting screen.
6
Use the on-screen keypad or the Keypad of the Control panel to enter the numeric value.
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-30~+30 1step = 0.1mm]
7