Adjust the center position when stapling on the SaddleStitcher SD-506.
Make this adjustment when the staple position deviates from the standard value.
To make correct adjustments, configure the following setting in advance.
Before printing, always pull out the Fold/Staple mode tray. Otherwise, a sample is not output even if you press Start on the Control panel.
A sample is output.
Standard value: a = -2.0 mm to +2.0 mm or less
[1] Paper center [2] Staple center position
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-20~+20 1step = 0.1mm]