Adjust the half-fold crease position of Creaser Unit CR-101 mounted on Saddle Stitcher SD-513.
Make this adjustment when the distance from the cover edge to the crease position on the top face of output paper deviates from the standard value.
To make correct adjustments, configure the following setting in advance.
A sample is output.
Standard value: a = -1.0 mm to +1.0 mm or less
(1) Folding line (2) Crease part
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-20~+20 1step = 0.1mm]