Home >
Adjustment > [Machine Adjustment] > [Printer Adjustment] > [Centering Adjustment]
[Centering Adjustment]
Overview
Adjust the image centering in the crosswise direction when printing.
Check the misalignment between the center of the output paper in the paper feed direction and the center of the image, and then make adjustments so that the image can be printed correctly.
The following setting is required to use this function.
- Perform [CD-Mag. Adjustment] in [Printer Adjustment].
- For details about [CD-Mag. Adjustment] in [Printer Adjustment], refer to [CD-Mag. Adjustment].
- For details about the mark that is printed on the front side of the chart, refer to About Charts.
Setting Procedure (When Adjusting the Front Side)
1
Press the adjustment target selection key to adjust.
4
Load A3 w or 11 e 17 w paper in the paper tray for adjustment selected in step 1, and select that paper tray.
5
Press Start on the Control panel.
A chart is output.
6
Fold the output paper in half in the center of the paper feed direction, and check the misalignment between fold line "a" and chart center line "b".
7
If any adjustments are required, press [Exit PrintMode] to return to the setting screen.
8
Use the on-screen keypad or the Keypad of the Control panel to enter the numeric value.
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-40~+40 1step = 0.1mm]
9
Repeat steps 2 to 8 until the desired result is obtained.
Setting Procedure (When Adjusting the Back Side)
4
Load A3 w or 11 e 17 w paper into any paper tray, and select that paper tray.
5
Press Start on the Control panel.
A chart is output.
6
Fold the output paper in half in the center of the paper feed direction, and check the misalignment between fold "a" and center line "b" of the chart of the back side.
7
If any adjustments are required, press [Exit PrintMode] to return to the setting screen.
8
Use the on-screen keypad or the Keypad of the Control panel to enter the numeric value.
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-40~+40 1step = 0.1mm]
9
Repeat steps 2 to 8 until the desired result is obtained.