Adjust the alignment width in the fore-edge direction (paper feed direction) of the body in the clamp section.
Make this adjustment when misalignment or distortion occurs in the fore-edge direction of the body during perfect binding using Perfect Binder PB-503.
When using any paper tray, you need to set a cover tray by selecting [Perfect Bind] of [Output Setting]. For details, refer to [Cover Tray].
A perfect binding sample is output.
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
(-) To reduce the distortion, (+) To reduce the misalignment
[Adj. Range:-20~+20 1step = 0.1mm]