Adjust the magnification in the paper feed direction when scanning the original using the Original glass.
Using this function allows you to vary the magnification of an image and adjust so that the image is correctly magnified.
The following setting is required to use this function.
A test chart is copied.
Standard value: 0% ^ 0.5% or less (full size)
Example: Within 200 mm ^ 1 mm
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:990~1010 1step = e0.001]