Adjust the fold position for [Tri-Fold-out] of the FoldingUnit FD-503. Make this adjustment when the fold position deviates from the standard value.
Confirm the following standard values in step 5.
Paper size | Standard value a | Standard value b |
---|---|---|
[A3w] | 282.0 mm | 144.0 mm |
[B4w] | 243.7 mm | 123.3 mm |
[SRA4w] | 214.3 mm | 108.6 mm |
[A4w] | 199.0 mm | 101.0 mm |
[12e18w] | 306.8 mm | 156.4 mm |
[11e17w] | 289.9 mm | 147.9 mm |
[8.5e14w] | 238.1 mm | 120.5 mm |
[8.5e11w] | 187.3 mm | 95.1 mm |
[8Kw] | 262.0 mm | 134.0 mm |
[Separate Scan] is automatically set to [Tri-Fold-out].
A sample is output.
Standard value: a, b = -1.5 mm to +1.5 mm or less
(1) [Fold 1], (2) [Fold 2]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]