Adjust the fold positions for Z-folding of the FoldingUnit FD-503. Make this adjustment when the fold position deviates from the standard value.
Confirm the following standard values in step 5.
Paper size | Standard value a | Standard value b |
---|---|---|
[A3w] | 105.5 mm | 108.5 mm |
[B4w] | 91.5 mm | 94.5 mm |
[SRA4w] | 80.5 mm | 83.5 mm |
[A4w] | 74.8 mm | 77.8 mm |
[12e18w] | 114.8 mm | 117.8 mm |
[11e17w] | 108.5 mm | 111.5 mm |
[8.5e14w] | 94.0 mm | - |
[8.5e11w] | 70.4 mm | 73.4 mm |
[8Kw] | 98.0 mm | 101.0 mm |
[Separate Scan] is automatically set to [Z-Fold].
A sample is output.
Standard value: a, b = -1.5 mm to +1.5 mm or less
(1) [Fold 1], (2) [Fold 2]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]