Adjust the interval between 2 punch holes and the paper edge on the FoldingUnit FD-503. Perform this function when the punch holes are very misaligned.
A sample is output.
Standard value: 10.5 mm -4.0 mm to +4.0 mm
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-40~+40 1step = 0.1mm]
Adjust the setting value by referencing the figure.