Adjust the staple pitch when stapling for Fold & Staple.
Make this adjustment when misalignment or distortion occurs on the paper stack during stapling.
[Output Setting] is automatically set to [Fold&Staple].
A sample is output.
Standard value: a = b /2 -3 mm to +3 mm or less
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-300~+300 1step = 0.1mm]