Adjust the fold position for [Tri-Fold-in] of the FoldingUnit FD-503. Make this adjustment when the fold position deviates from the standard value.
Confirm the following standard values in step 5.
Paper size | Standard value a | Standard value b |
---|---|---|
[A3w] | 139.0 mm | 142.0 mm |
[B4w] | 120.3 mm | 123.3 mm |
[SRA4w] | 105.6 mm | 108.6 mm |
[A4w] | 98.0 mm | 101.0 mm |
[12e18w] | 151.4 mm | 154.4 mm |
[11e17w] | 142.9 mm | 145.9 mm |
[8.5e14w] | 117.5 mm | 120.5 mm |
[8.5e11w] | 92.1 mm | 95.1 mm |
[8Kw] | 129.0 mm | 132.0 mm |
[Separate Scan] is automatically set to [Tri-Fold-in].
A sample is output.
Standard value: a, b = -1.5 mm to +1.5 mm or less
(1) [Fold 1], (2) [Fold 2]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]