Adjust the fold position for [Double Parallel] of the FoldingUnit FD-503. Make this adjustment when the fold position deviates from the standard value.
Confirm the following standard values in step 5.
Paper size | Standard value a | Standard value b |
---|---|---|
[A3w] | 208.5 mm | 103.8 mm |
[B4w] | 180.5 mm | 89.8 mm |
[SRA4w] | 158.5 mm | 78.7 mm |
[A4w] | 147.0 mm | 73.0 mm |
[12e18w] | 227.1 mm | 113.1 mm |
[11e17w] | 214.4 mm | 106.7 mm |
[8.5e14w] | 176.3 mm | 87.7 mm |
[8.5e11w] | 138.2 mm | 68.6 mm |
[8Kw] | 193.5 mm | 96.3 mm |
[Separate Scan] is automatically set to [Double Parallel].
A sample is output.
Standard value: a, b = -1.5 mm to +1.5 mm or less
(1) [Fold 1], (2) [Fold 2]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
[Adj. Range:-50~+50 1step = 0.1mm]