Adjust the position to start gluing on the body.
Make this adjustment when there is a problem with the glue amount when performing perfect binding using Perfect Binder PB-503.
When using any paper tray, you need to set a cover tray by selecting [Perfect Bind] of [Output Setting]. For details, refer to [Cover Tray].
A perfect binding sample is output.
(1) Body (2) Gluing start position in Ahead mode (3) Gluing start position in Back mode
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
(-) To increase, (+) To decrease
[Adj. Range:-128~+127 1step = 0.1mm]