Granularity Setting

Adjust development conditions when an image noise (degradation of granularity) or sweeping (a phenomenon that causes toner to be swept to the rear edge in the paper feed direction of a halftone solid image, causing the rear edge to darken) occurs.

Each setting value is as follows. The default is set to +3(Normal). As a lower value is specified, the granularity reduces, which prevents a sweeping phenomenon.

Setting value:

+3(Normal): Sets top priority to the granularity.

+2: Sets the granularity to the middle priority level.

+1: Sets a prevention of sweeping phenomenon above the granularity.

Tips
  • If the setting is changed, Gamma Automatic Adjustment is performed when the display has returned to the normal screen.

  1. Follow the procedure on Displaying the [Administrator Setting Menu] Screen to display the Administrator Setting Menu screen.

  2. Press System Setting on the Administrator Setting Menu screen, and then press Expert Adjustment, Process Adjustment, and Granularity Setting in sequence.

  3. Press the desired setting button.

  4. Press OK to complete the setting.

    • supplementary explanationTo cancel the change, press Cancel.