Temperature Adjustment

Control the condition of glue to be dried by setting temperature on the sensors inside the melt tank and of the glue apply roller using Perfect Binder PB-503.

The following two types of sensors are provided.

Glue Tank -Low:

Adjust the temperature to control the tank heater.

Low temperature: increases glue viscosity, High temperature: decreases glue viscosity

Initial: 185°C

Recommended: 180 °C to 190 °C

Glue Apply Roller:

Adjust the temperature to control the roller heater. This also supports heating of the glue.

Low temperature: increases glue viscosity, High temperature: decreases glue viscosity

Initial: 165 °C

Recommended: 160 °C to 170 °C

NOTICE
  • Do not make unnecessary change in the temperature setting of sensors inside the melt tank.

  1. Press Adjustment on the MACHINE screen to display the Adjustment Menu screen.

  2. Press Finisher Adjustment, Perfect Binder Adjustment, and Temperature Adjustment in sequence.

  3. Load cover paper in either Perfect Binder Cover Tray or any other tray.

  4. Load paper for body sets in the desired tray.

  5. Press the key of the item to be adjusted.

  6. Press Print Mode.

  7. Select the tray loaded with paper for body sets.

  8. Press Start on the control panel.

    A sample pattern of perfect-bound book is printed.

  9. Check that the glue applied on the body set is in proper condition.

  10. If any adjustment is required, press Exit PrintMode to return to the Temperature Adjustment screen.

  11. Use the touch panel keypad to enter the set value.

  12. Repeat steps 6 to 11 until the desired result is obtained.

  13. Press Return.