Checking Color Density Control Error

An error number dialog may be displayed while the machine is in print mode performing Color Density Manual Control or Each Paper Type Color Adj..

The following list of error numbers provides the event and remedy corresponding to the error number to be displayed in the dialog.

Follow the instruction on the list, then press Close.

Error No.

Event

Remedy

001

The color sensor adjustment data for each paper type might have been created by a spectrophotometer other than those specified.

Create color sensor adjustment data for each paper type using the Spectrophotometer i1-iSisXL, i1-Pro or i1-Pro2, or FD-5 BT. Do not use any spectrophotometer other than specified.

002

There is a difference in the number of colorimetric charts between those assigned to the file name and actual sheet count.

Reconfirm the file name, then remeasure all the charts with the spectrophotometer.

003

There may be a problem with the chart that has been measured using the spectrophotometer.

Check the measured chart again, then remeasure it using the spectrophotometer.

004

There may be a failure in the spectrophotometer.

Adjust the spectrophotometer, then remeasure the charts.

005

The patches in the charts may be measured in the wrong order.

Reconfirm the order to measure the patches in the charts, then remeasure all the charts using the spectrophotometer.

014

The data currently loaded from the output chart images during the Color Density Manual Control or Each Paper Type Color Adj. might be the cause.

Carry out the Color Density Manual Control or the Each Paper Type Color Adj. again. If the same error number is displayed again, contact your service representative.

015

The data loaded from the chart images previously output by the machine during the Color Density Manual Control or Each Paper Type Color Adj. might be the cause.

Carry out the Color Density Manual Control or the Each Paper Type Color Adj. again. If the same error number is displayed again, contact your service representative.

021

Abnormalities occurred in calculating the regression curve of the colorimetric data when the Each Paper Type Color Adjustment List was registered.

Measure the chart using the spectrophotometer again, and re-register the Each Paper Type Color Adjustment List. If the same error number is displayed again, contact your service representative.

026

An input parameter error occurred when the Each Paper Type Color Adjustment List was registered.

Carry out the registration of Each Paper Type Color Adjustment List again. If the same error number is displayed again, contact your service representative.