Carry out calibration using Exact Color.
The normal calibration adjusts the gradation output density for each single color (CMYK) while the Exact Color calibration adjusts the mixed colors (color with 2 or 3 colors mixed or gray balance), enhancing the color reproduction accuracy.
Create an adjustment table and provide feedback on the adjustment table to improve the accuracy of color reproduction.
The below screens may differ from the actual ones depending on the usage environment or the application version and revision.
If [Execute Wizard of Exact Color] is not displayed on the [Calibration Manager] screen, click [Show Exact Color].
"FB" at top right of the screen refers to "Feedback", and [FB1]"" refers to the first feedback.
The [Print Chart] screen is displayed.
[Copies] can be specified with 1 to 99.
The setting contents are also displayed in the next setting.
To perform [Gamma Automatic Adjustment], select the [Engine Calibration] check box.
Color charts are printed. When printing is completed, the display returns to the [1.Create of current table(ExCol)] screen.
The operation method varies depending on the connected colorimeter. Follow the on-screen instructions to perform the operation.
If the measurement line is incorrect, a warning message is displayed. You can select whether to retry measuring using the correct line, or whether to proceed to the next line.
You cannot click [OK] until the acquirement of measurement data is completed.
Patches on the preview are displayed in gray before measuring, and in color after measuring.
Each patch value is displayed in the measurement data list.
If you click a color patch on the preview, the corresponding line is selected in the measurement data list. Also, if you select a line in the measurement data list, the corresponding color patch is selected on the preview.
: Saves measurement data in any local folder.
: Imports the saved measurement data.
To end measuring, proceed to step 11.
To continue measuring, proceed to step 12.
The measurement data can be checked on the [Calibration Manager] screen.
Measurement data continues to be displayed until the [Calibration Manager] screen closes or the data is initialized. For details about initialization, refer to Setting Procedure (Initializing Calibration Data).
The Exact Color adjustment performed until that time and the [Accuracy Measurement] result are reflected on the [Calibration Manager] screen.
To register measurement data, proceed to step 13.
Clicking [Cancel] discards the measurement result and closes the [1.Create of current table(ExCol)] screen. Then, the display returns to the [Calibration Manager] screen.
The confirmation dialog box is displayed.
You can register measurement data in the Image Controller to apply it to printing.
Measurement data is registered in the representative location of the group specified in [Calibration Group]. For details, refer to [Settings].