Output printed items with abnormalities detected during automatic inspection to the Purge tray, and then reprint.
This section uses an example of a system configuration in which printed items on which an abnormality was detected, and any remaining paper within that machine, are output to the Purge tray of Relay Unit RU-702.
Assumed Operating Environment
Item Name | Contents |
---|---|
OS | Windows 10 |
Application | Adobe Acrobat Reader DC |
Printer Driver | PS Plug-in Driver |
Option | Image Controller Intelligent Quality Care Unit IQ-501 Auto Inspection Unit UK-301 Relay Unit RU-702 Video Interface Kit VI-514 Video Interface Kit VI-515 |
You can also configure this setting by accessing Utility/Counter, [User Setting], and then [Common Setting], or Utility/Counter, [Administrator Setting], and then [Common Setting].
For details about setting examples, refer to "Setting example" (described after the procedure).
If an abnormality is detected during printing, the printing paper remaining in that machine is output to the [Purge Tray] at the same time as the printing paper on which the abnormality was detected.
Setting example
Item | Setting Value |
---|---|
[Automatic Reprint when Deviation/Out of Range was Detected] | [ON] |
[Output Tray for Out of Range] | [Purge Tray] |