Configure settings for the periodical both-side adjustment. This menu item is to be displayed on the machine mounted with Integrated Color Care Unit IQ-501.
Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.
Press [Quality Adjustment] and [Periodical Both Sides Adj.] in sequence.
Change any setting as needed.
Menu item | Description | Setting value: |
---|---|---|
[Period. Both Sides Auto Adj.] | Allows you to select whether to periodically output charts and make the both-side adjustment when printing of the number of sheets specified in [Adjustment Interval] is completed. If you select [ON], you can set [Periodical Adjustment] to [ON] or [OFF] for each tray in the [AutoMeasure] tab of the [Both Sides Adjust] screen. | ON, OFF (Default) |
[Adjustment Interval] | Specify the interval to automatically make the both-side adjustment. | If you select [ON] in [Period. Both Sides Auto Adj.], you can press [Change] to specify 100 to 9,999 sheets. (Default: 500 sheets) |
[Deviation Check] | Select whether to check a deviation. | ON, OFF (Default) If you select [ON], you can specify the defined value (deviation level) used to judge that a deviation occurs. The defined value between 0.5 mm and 10.0 mm can be specified. (Default: 2.0 mm) |
Press [OK].