Adjust any misalignment of printing positions on the front and back sides that occurs during 2-sided printing.
When you change the paper to load into a paper tray, always perform [Both Sides Adjust].
The rightmost tab on the Both Sides Adjust screen varies depending on the optional devices mounted on this system.
Intelligent Quality Care Unit IQ-501 | Scanner | Tab display |
---|---|---|
Provided | Equipped | [AutoMeasure] or [Scan Meas.] Setting is required to display [Scan Meas.]. For details, contact your service representative. |
Unequipped | [AutoMeasure] | |
None | Equipped | [Scan Meas.] |
Unequipped | Blank |
Screen access
Touch panel - [MACHINE] - [Both Sides]
Touch panel - [MACHINE] - [Paper Setting] - [New Setting] - [Both Sides Adj.]
Touch panel - [MACHINE] - [Paper Setting] - [Change Set] - [Both Sides Adj.]
Setting item | Description |
---|---|
[Tray Setting] | Select the desired Paper tray from the list. |
[Reset Adj. Data] | If you press [Yes] in the dialog box that is displayed by pressing this option, all the numeric values in [Both Sides] are reset. The following settings on the [AutoMeasure] screen are not reset.
|
Adjust the magnification and position of the image to print on the front side. | |
Adjust the magnification and position of the image to print on the back side. | |
Separate charts are prepared to adjust the front side and the back side. Measure the measurement points of the output chart by, for example, using a scale, and then enter the measurement value and perform the adjustment. | |
Perform adjustments when the entire image is rotated clockwise or counterclockwise or a diagonal skew is detected. | |
This system provides the chart used to adjust [Deformation]. To make adjustments, measure the measurement points of the output chart using a scale, and then enter the measurement value. | |
Simply adjust only the zoom ratio and the image position of the back side based on the image position on the front side. | |
Read the output chart using Intelligent Quality Care Unit IQ-501, and automatically perform Both Sides Adjustment. | |
Configure settings to perform [Periodical Both Sides Adj.] for each paper tray. | |
Configure settings to perform [Both Sides Adj. Before Job] for each paper tray. | |
Read a chart using the scanner of this system, and automatically adjust the magnification and print position of the front and back sides. |