Daily Checking of Image Quality
Overview
After adjusting the image quality, or if you discover abnormalities in the image, check the image quality using the work flow detailed below.
The following option is required when performing this flow.
- Intelligent Quality Care Unit IQ-501
When Checking Color Reproducibility After Adjusting Image Quality
Step 1
Register and set [Printer Profile], which has been configured with the optimal condition settings, to [Target Profile] as the target (standard image condition). Alternatively, select [Target Profile] for the target printing standard.
Step 2
Check the value of ΔE, and decide whether or not maintenance is required.
If there are no changes to the target profile, only perform color validation thereafter.
When Checking the Machine Status If There Is an Issue in the Image Quality
Step 1
Set [DetailedDiagnosis/Sync.SimpleDiagnosis] to [ON].
Step 2
[Detailed Diagnosis] is performed automatically in the event of an abnormality. Check the image quality after performing [Detailed Diagnosis] by outputting an AQA Reference chart.