Adjust the magnification in paper feed direction when scanning the original from the original glass.
Make this adjustment after completing Machine Adjustment - Printer Adjustment - FD-Mag. Adjustment.
Press Adjustment on the MACHINE screen to display the Adjustment Menu screen.
Press Machine Adjustment, Scan Adjustment, and FD-Mag. Adjustment in sequence.
Press Print Mode.
Load A3 short edge feed paper or 11 17 short edge feed paper, then select that tray.
Position the test chart on the original glass, then press Start on the control panel.
A sample pattern will be output.
Check the misalignment by comparing the original and the output.
Allowance:
0 ± 0.5% or less (full size)
Within 200 mm ± 1 mm
If any adjustment is required, press Exit PrintMode to return to the FD-Mag. Adjustment screen.
Use the touch panel keypad or the keypad on the control panel to enter the setting data.
supplementary explanationUse +/- to specify the value to be positive or negative.
supplementary explanationPress Set to change the Current Value.
supplementary explanationAdjustment Range: 990 (Short) to 1010 (Long) (1 step = x 0.001)
Repeat steps 3 to 8 until the desired result is obtained.
Press Return.
The screen returns to the Scan Adjustment Menu screen.