The spectrophotometers to read the chart are as follows.
i1-iSisXL
i1-Pro/i1-Pro2
FD-5 BT
FD-9
Each of i1-iSisXL/FD-9 and i1-Pro/i1-Pro2 provides two types of charts: Type 1 for standard adjustment and Type 2 for high-accuracy adjustment. FD-5 BT provides three types of charts: Type 1 for standard adjustment, Type 2 for high-accuracy adjustment, and Type 3 for high-accuracy adjustment in strip measurement.
Output a chart to which the screen type that has been set by the machine was applied.
Before outputting the chart, an appropriate screen and paper must be selected.
[Stochastic], however, cannot be selected to output a chart.
The screen type can be changed in UTILITY. For details, refer to Custom Screen: Selecting the Screen Type.
Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.
Press [Density Balance Adjustment] and [Density Balance Chart Output] in sequence.
Select the desired spectrophotometer and chart type, and press [Print Mode].
[Type 1] is for standard adjustment, and both [Type 2] and [Type 3] are for high-accuracy adjustment.
To use the Spectrophotometer i1-iSisXL or FD-9, select [Type 1] or [Type 2] in [Measure Spectrophotometer-1 (i1-iSisXL/FD-9)].
To use the Spectrophotometer i1-Pro/i1-Pro2, select [Type 1] or [Type 2] in [Measure Spectrophotometer-2 (i1-Pro/i1-Pro2)].
To use the Spectrophotometer FD-5 BT, select [Type 1], [Type 2], or [Type 3] in [Measure Spectrophotometer-3 (FD-5 BT)].
Press [Quality Adj.].
Press [] on the right side of [Screen Pattern] to display the desired screen.
If necessary, you can press [Screen Pattern] to display the [Screen Pattern] screen and select any screen. Select a screen, and press [OK].
Press [Close] on the [Quality Adjustment] screen.
Check the paper settings.
If the settings differ from the specifications of the media currently set, press [Paper Setting] then press [Recall] or [Change Set] to change the paper settings.
Press Start on the control panel.
A test chart is printed.
If [Type 1] is selected for [Measure Spectrophotometer-1 (i1-iSisXL/FD-9)] in step 3, one sheet is output. If [Type 2] is selected, two sheets are output.
For [Measure Spectrophotometer-2 (i1-Pro/i1-Pro2)], the chart is output on one sheet even when either of [Type 1] or [Type 2] is selected.
For [Measure Spectrophotometer-3 (FD-5 BT)], the chart is output on one sheet even when any one of [Type 1], [Type 2], or [Type 3] is selected.
Press [Exit PrintMode].
The screen returns to the [Density Balance Chart Output] screen.
Press [Return].
The screen returns to the [Density Balance Adjustment Menu] screen.