Home Settings and AdjustmentsList of Adjustment Menu Items

List of Adjustment Menu Items

Adjustment item and description

Objects/range of adjustment

[01 Machine Adjustment]

[01 Printer Adjustment]

[01 Centering Adjustment]

Adjust the image position in the crosswise direction of the printer engine.

Prerequisite: CD-Mag. Adjustment is completed.

Adjustment Range:

-40 (Front) to +40 (Back)

(1 step = 0.1 mm)

[02 FD-Mag. Adjustment]

Adjust the magnification in paper feed direction in the printer engine.

Adjustment Range:

-100 (Short) to +100 (Long)

(1 step = 0.01%)

[03 CD-Mag. Adjustment]

Adjust the magnification in crosswise direction in the printer engine.

Adjustment Range:

-100 (Short) to +100 (Long)

(1 step = 0.01%)

[04 Stop Immediately Timing Adj.]

Reduce the damage of paper at the end of printing or improve the performance of conveyance just before the end of printing.

Adjustment Range:

-30 (Quicken the stop timing) to +30 (Slow the stop timing)

(1 step = 10ms)

[02 Execute Adjust Operation]

Select a quality correction item and adjust the quality for your purpose.

Gamma Automatic Adj., Color Regist. Auto.Adj., Toner Refresh Mode, Belt Refresh Mode

[03 Density Balance Adjustment]

[01 Density Balance Chart Output]

Output the chart for density balance adjustment.

Objects of adjustment:

Measure Spectrophotometer-1 (i1-iSisXL/FD-9)

  - Type1: Simple checking chart (1 sheet for 8-point measurement)

  - Type2: Detailed checking chart (2 sheets for 16-point measurement)

Measure Spectrophotometer-2 (i1-Pro/i1-Pro2)

  - Type1: Simple checking chart (for 1-point measurement)

  - Type2: Detailed checking chart (for 3-point measurement)

Measure Spectrophotometer-3 (FD-5 BT)

  - Type1: [Spot] Simple checking chart (for 1-point measurement)

  - Type2: [Spot] Detailed checking chart (for 3-point measurement)

  - Type3: [Strip] Detailed checking chart (for 3-point measurement)

[02 Density Balance Data Reg/Del]

Load the colorimetric data, or manually register the data on the machine.

[04 Maximum Density Adjustment]

Adjust the maximum density for each of Y, M, C, and K. The machine will start the Gamma Automatic Adjustment after you change the maximum density. When the Gamma Automatic Adjustment is completed, proceed to the calibration with the image controller.

Yellow: -10 (Light) to +10 (Dark)

Magenta: -10 (Light) to +10 (Dark)

Cyan: -10 (Light) to +10 (Dark)

Black: -10 (Light) to +10 (Dark)