AutoMeasure adjustment

This function scans both sides of adjustment charts printed out in Print Mode using Integrated Color Care Unit IQ-501, and automatically makes the both-side adjustment. After adjustment, each adjustment value (Zoom, Image Shift, and Rotate/Skew) on this screen is updated.

The magnification and printing position of the adjustment chart printed on both sides are scanned using Integrated Color Care Unit IQ-501, and adjustment values are obtained automatically. When multiple adjustment charts are printed, adjustment values are obtained from the average, thereby enabling highly accurate adjustment to be carried out. Up to 20 adjustment charts can be printed out collectively.

The AutoMeasure adjustment is not available on a machine that is not equipped with Integrated Color Care Unit IQ-501.

Tips
  • If you press Adjustment - Quality Adjustment - Periodical Both Sides Adj. on the MACHINE screen and set Period. Both Sides Auto Adj. to ON, you can set Periodical Adjustment to ON or OFF for each tray. Periodical Adjustment is available for the tray for which ON is set. For details, refer to [Periodical Both Sides Adj.].

  1. Press Both Sides on the MACHINE screen.

  2. Press AutoMeasure, then press Print Mode, after selecting the tray loaded with paper for adjustment.

  3. Enter the necessary number of adjustment charts, then press Start on the control panel.

    • supplementary explanationUp to 20 adjustment charts can be printed out. As the number of charts increases, the accuracy of adjustment values rises.

  4. After adjustment charts have been printed out, press Exit PrintMode.

  5. The AutoMeasure screen is displayed, and each adjustment value on this screen is updated.

    • supplementary explanationPrint out one adjustment chart, and check it.

  6. Press Close.

    Now, the AutoMeasure adjustment is completed.