Setting data for account track data
Begin the data with #EKC_TAB.
Max. 1,000 files can be edited.
A line should include PASSWORD, NAME, and LIMIT, separated by a tab.
PASSWORD is a password for account (max. 8 bytes).
NAME is an account name (max. 8 bytes).
LIMIT is the upper limit (0 to 99999999).
Setting data for E-mail data
Begin the data with #IP_EMAIL.
A line should include NAME, ADDRESS, REFERENCE, and DAILY, separated by a tab.
NAME is a registration name (max. 24 bytes).
ADDRESS is a mail address (max. 256 bytes).
REFERENCE is a search string (max. 24 bytes).
DAILY specifies whether or not to register for regular use (1: Yes, 0: No).
Setting data for HDD data
Begin the data with #IP_HDD.
A line should include NAME, NUMBER, PASSWORD, REFERENCE, or DAILY, separated by a tab.
NAME is a registration name (max. 24 bytes).
NUMBER is a box name (Image Controller IC-605: 1 to 999999999, Image Controller IC-313, Image Controller IC-314, or Image Controller IC-417: Max. 64 bytes).
PASSWORD is a password (max. 8 bytes).
REFERENCE is a search string (max. 24 bytes).
DAILY specifies whether or not to register for regular use (1: Yes, 0: No).
Setting data for FTP data
Begin the data with #IP_FTP.
A line should include NAME, ADDRESS, FILEPATH, LOGINNAME, PASSWORD, PORT, REFERENCE, DAILY, and PROXY being delimited by a tab.
NAME is a registration name (max. 24 bytes).
ADDRESS is a host address (max. 253 bytes).
FILEPATH is a file path (max. 127 bytes).
LOGINNAME is a login name (max. 32 bytes).
PASSWORD is a password (max. 32 bytes).
PORT is a port number (1 to 65535).
REFERENCE is a search string (max. 24 bytes).
DAILY specifies whether or not to register for regular use (1: Yes, 0: No).
PROXY specifies whether or not to use a proxy server (1: Yes, 0: No).
Setting data for SMB data
Begin the data with #IP_SMB.
A line should include NAME, ADDRESS, FILEPATH, LOGINNAME, PASSWORD, REFERENCE, or DAILY being separated by a tab.
NAME is a registration name (max. 24 bytes).
ADDRESS is a host address (max. 253 bytes).
FILEPATH is a file path (max. 255 bytes).
LOGINNAME is a login name (max. 32 bytes).
PASSWORD is a password (max. 32 bytes).
REFERENCE is a search string (max. 24 bytes).
DAILY specifies whether or not to register for regular use (1: Yes, 0: No).
Setting data for WebDAV data
Begin the data with #IP_WEB.
A line should include NAME, ADDRESS, FILEPATH, LOGINNAME, PASSWORD, DOMAINNAME, PORT, REFERENCE, DAILY, PROXY, and SSL being delimited by a tab.
NAME is a registration name (max. 24 bytes).
ADDRESS is a host address (max. 253 bytes).
FILEPATH is a file path (max. 142 bytes).
LOGINNAME is a login name (max. 64 bytes).
PASSWORD is a password (max. 32 bytes).
DOMAINNAME is a domain name (max. 64 bytes).
PORT is a port number (1 to 65535).
REFERENCE is a search string (max. 24 bytes).
DAILY specifies whether or not to register for regular use (1: Yes, 0: No).
PROXY specifies whether or not to use a proxy server (1: Yes, 0: No).
SSL specifies whether or not to use the SSL communication (1: Yes, 0: No).
Setting data for Paper setting data
The lines after #CUSTOM_SIZE describe the information for the registered custom sizes (20 entries). A line should include NUMBER, NAME, and various set values, delimited by a tab.
Then the lines after #PAPER_SETTING describe the information for the registered paper profiles (500 entries). A line should include NUMBER, NAME, and various set values, delimited by a tab.
NUMBER is a registration number. It can take from 1 to 20 for custom sizes, and 1 to 500 for paper profiles.
NAME is a custom size name (max. 20 bytes) or a paper profile name (max. 50 bytes).