FD-Mag. Adjustment

Adjust the magnification in paper feed direction in the printer engine. This adjustment value will be the standard for Both Sides Adjust in Paper Setting.

Objects of Adjustment:

Side1: Printer FD-Mag.

Side2: Tray1 to Tray11

  1. Press Adjustment on the MACHINE screen to display the Adjustment Menu screen.

  2. Press Machine Adjustment, Printer Adjustment, and FD-Mag. Adjustment in sequence.

  3. Press the key of the object to be adjusted.

    • supplementary explanationSelect Side1 or Side2.

    • supplementary explanationIf Side2 is selected, select the tray to be adjusted.

  4. Press Print Mode.

  5. Load A3 short edge feed paper or 11 17 short edge feed paper into the tray to be adjusted, then select that tray.

  6. Press Start on the control panel.

    A sample pattern will be output.

    • supplementary explanationOn the front side of the chart, mark will be printed so that you can tell which tray is used to print the chart. For details, refer to Chart.

  7. Measure the resultant magnification in the paper feed direction.

    Allowance: ± 0.5% or less (full size)

    within 205.7 mm ± 1 mm

  8. If any adjustment is required, press Exit PrintMode to return to the FD-Mag. Adjustment screen.

  9. Use the touch panel keypad or the keypad on the control panel to enter the setting data.

    Adj. Range: -10~+10 1 step = 0.05%

    • supplementary explanationSide1: Printer FD-Mag.

    Adj. Range: -10~+0 1 step = 0.05%

    • supplementary explanationSide1, Side2: Tray1 to Tray11

    [-] Short [+] Long

    • supplementary explanationUse +/- to specify the value to be positive or negative.

    • supplementary explanationPress Set to change the Current Value.

  10. Repeat steps 4 to 9 until the desired result is obtained.

  11. Press Return.

    The screen returns to the Printer Adjustment Menu screen.