Adjust the magnification in crosswise direction when scanning the original from the original glass.
Make this adjustment after completing Machine Adjustment - Printer Adjustment - CD-Mag. Adjustment.
Press Adjustment on the MACHINE screen to display the Adjustment Menu screen.
Press Machine Adjustment, Scan Adjustment, and CD-Mag. Adjustment in sequence.
Press Print Mode.
Load A3 short edge feed or 11 17 short edge feed paper in any tray, and select the tray.
Position the test chart on the original glass, then press Start on the control panel.
A test chart is copied.
Measure the width in the crosswise direction, and compare the measured value with the chart.
Allowance: 0 ± 0.5% or less (full size)
Example: Within 200 mm ± 1 mm
If any adjustment is required, press Exit PrintMode to return to the CD-Mag. Adjustment screen.
Use the touch panel keypad or the keypad on the control panel to enter the setting data.
Adj. Range: 990~1010 1 step = x 0.001
[-] Short [+] Long
supplementary explanationUse +/- to specify the value to be positive or negative.
supplementary explanationPress Set to change the Current Value.
Repeat steps 3 to 8 until the desired result is obtained.
Press Return.
The screen returns to the Scan Adjustment Menu screen.