To display: [Utility] - [Administrator] - [Security] - [PKI Settings]
Make settings to enable SSL communication using the certificate of this machine.
To display: [Utility] - [Administrator] - [Security] - [PKI Settings] - [Enable SSL Version]
Select a login mode to enable SSL communication. Also, specify the range of the SSL version to be used.
Setting | Description |
---|---|
[Mode using SSL/TLS] | Select a login mode to establish SSL communications (default: [None]).
|
[Encryption Strength] | Displays the SSL encryption strength (AES-256 only). |
[SSL/TLS Version Setting] | Select the target SSL version respectively from [Minimum] and [Maximum]. |
To display: [Utility] - [Administrator] - [Security] - [PKI Settings] - [Protocol Setting]
If there are multiple certificates on this machine, you can use the certificates properly according to the purpose (protocol).
Specify the desired protocol in the protocol list, select [Edit], and select the target certificate.
Protocol | Application |
---|---|
[SSL]: [HTTP Server] | If this machine is used as an http server, it encrypts transmission from a client to the machine. For example, it is used for the following application.
|
[SSL]: [E-mail TX (SMTP)] | If this machine is used as an SMTP client, it submits a certificate of the machine according to a request from the E-mail server (SMTP). |
[SSL]: [E-mail RX (POP)] | If this machine is used as an POP client, it submits a certificate of the machine according to a request from the E-mail server (POP). |
[SSL]: [TCP Socket] | If this machine is used as a TCP Socket client, it submits a certificate of the machine according to a request by the TCP Socket server. |
[SSL]: [LDAP] | If this machine is used as an LDAP client, it submits a certificate of the machine according to a request by the LDAP server. |
[SSL]: [WebDAV Client] | If this machine is used as a WebDAV client, it submits a certificate of the machine according to a request by the WebDAV server. |
[SSL]: [OpenAPI] | If this machine is used as an OpenAPI server, it encrypts transmission from an OpenAPI client to the machine. |
[SSL]: [Web Service] | If this machine is used as a Web service server, it encrypts transmission from a client to the machine. This option is used when your Windows computer accesses the machine via HTTPS. |
[SSL]: [IPsec] | Used to activate IPsec communication on this machine. |
[SSL]: [Remote Panel] | When the screen of this machine is operated remotely with the dedicated software, it is used for the following applications:
|
[SSL]: [ThinPrint] | If this machine is used as a ThinPrint client, it submits a certificate of the machine according to a request by the ThinPrint server (.print Engine). After this machine validates the certificate, the ThinPrint server performs encrypted communication. Specify the certificate of this machine to use for communication that is issued by the Certificate Authority (CA). |
[IEEE802.1X] | If this machine is used as an IEEE802.1X authentication client, it is used for the following applications:
|
[S/MIME] | When sending an S/MIME E-mail, it attaches a certificate of this machine to ensure the sender of the E-mail. |
To display: [Utility] - [Administrator] - [Security] - [Limiting Access to Destinations]
Limit the access to destinations for each user. Restrict destinations that can be browsed by users by combining [Apply Levels to Destinations] and [Apply Levels/ Groups to Users].
To display: [Utility] - [Administrator] - [Security] - [Limiting Access to Destinations] - [Store Group]
Register a reference allowed group. In a reference allowed group, destinations and users can be registered, and such users can reference destinations registered in the same group.
Setting | Description |
---|---|
[Group Name] | Enter the group name (using up to 24 single-byte characters or 12 double-byte characters). |
[Access Allowed Level] | To manage the address book by combining the reference allowed level and reference allowed group, select a reference allowed level of the reference allowed group (default: [Level 0]). |
To display: [Utility] - [Administrator] - [Security] - [Limiting Access to Destinations] - [Apply Levels to Destinations]
Assign a reference allowed group or level to the registered destination.
Setting | Description |
---|---|
[Destinations Levels Setting Type] | Select a registered destination to assign a reference allowed group or reference allowed level to. |
[Apply Group] | Assign a reference allowed group to the registered destination you have selected. Before you can assign a reference allowed group, you need to register the reference allowed group in [Store Group]. |
[Apply Level] | Assign a reference allowed level to the registered destination you have selected (default: [Level 0]). |
To display: [Utility] - [Administrator] - [Security] - [Limiting Access to Destinations] - [Apply Levels/ Groups to Users]
Assign a reference allowed group or level to the user. You can combine reference allowed group and reference allowed level settings.
Setting | Description |
---|---|
[Apply Levels/Groups to Users] | Select a user to assign a reference allowed group or reference allowed level to. |
[Apply Group] | Assign a reference allowed group to the registered user you have selected. Before you can assign a reference allowed group, you need to register the reference allowed group in [Store Group]. |
[Apply Level] | Assign a reference allowed level to the user you have selected (default: [Level 0]). |
To display: [Utility] - [Administrator] - [Security] - [Restrict User Access]
Configure settings to restrict change or deletion operations for users.
Setting | Description |
---|---|
[Registering and changing addresses] | Select whether to allow the user to register or change an address, a favorite scan setting, or favorite fax setting in basic style, and also a scan/fax program in classic style (default: [Allow]). |
[Biometric/IC Card Information Registration] | When allowing the user to register or when deleting the user’s biometric or IC card information, set this option to ON (default: OFF). |
[Synchronize User Authentication / Account Track By User] | When allowing the user to change the setting for synchronization between user authentication and account track, set this option to ON (default: ON). This setting is displayed when [Synchronize User Authentication / Account Track] is set to [Synchronize by User] in [Utility] - [Administrator] - [User Auth/Account Track] - [Authentication Method]. |
[Using the program function] | Select whether to allow the user to use a favorite setting of basic style and a program of classic style (default: [Allow]). |
[Select multiple destinations] | Select whether to allow the user to perform broadcasting (default: [Allow]). |
[Continuous selection of broadcast destinations] | When displaying the confirmation screen to successively select destinations, set this option to [Restrict] (default: [Restrict]). This setting is available when [Select multiple destinations] is set to [Allow]. |
[Select all Groups] | When displaying the [Select All] key on the Group destination specification screen, set this option to [Allow] (default: [Restrict]). This setting is available when [Select multiple destinations] is set to [Allow]. |
[Changing job priority] | Select whether to allow the user to change the job priority order (default: [Allow]). |
[Delete other user jobs] | Select whether to allow another user to delete a job (default: [Restrict]). |
[Changing zoom ratio] | Select whether to allow the user to change the registered zoom ratio (default: [Allow]). |
[Change registered overlay] | Select whether to allow the user to overwrite or delete a registered overlay image (default: [Allow]). |
To display: [Utility] - [Administrator] - [Security] - [Administrator Password Setting]
Change the administrator password of this machine (using up to 64 single-byte characters). Be sure to remember the changed password so that you do not forget it.
To display: [Utility] - [Administrator] - [Security] - [Copy Program Lock Settings]
Restrict a change or deletion of the registered copy or image adjustment program name. This option can be specified for each program.
To display: [Utility] - [Administrator] - [Security] - [Lock "My Settings" item (Copy)]
Prohibit editing or deletion of the registered favorite copy setting.
To display: [Utility] - [Administrator] - [Security] - [Delete Saved Copy Program]
Delete a registered copy or image adjustment program.
To display: [Utility] - [Administrator] - [Security] - [Admin. Password Change Permission Sett.]
Specify whether to allow a change of the administrator password for each function.
Setting | Description |
---|---|
[Allow password change] | When allowing the user to change the administrator password, set this option to ON (default: ON). |
[Function] | Specify the functions for which the administrator password can be changed.
|
To display: [Utility] - [Administrator] - [Security] - [User Box Administrator Setting]
If the administrator of this machine wishes to delegate the User Box management or the management of files in the User Box to a particular person, assign a User Box administrator.
The User Box administrator can register or delete User Boxes of all users and also use files in User Boxes and System User Box. If [External Memory] is selected for the System User Box, only the file printing is available.
Setting | Description |
---|---|
[User Box Administrator Setting] | When allowing the User Box administrator, set this option to ON (default: OFF). |
[User Box Password] | Enter the password of User Box Administrator (using up to 64 single-byte characters). |
[Re-enter User Box Administrator Password] | Retype the User Box administrator password for confirmation. |
[E-mail Address] | Enter the E-mail address of the User Box Administrator (using up to 317 single-byte characters, excluding a space). If the total file size in the SMB folder exceeds 90% of the available capacity in the storage, it is notified to the E-mail address of the User Box administrator. If the User Box administrator's E-mail address is not set, the notification is sent to the E-mail address of the machine administrator. |
To log in as a User Box administrator, enter the following information on the login screen.
To display: [Utility] - [Administrator] - [Security] - [Administrator Security Levels]
From those items that are set up by the administrator, select levels at which users are authorized to change settings (default: [Restrict]).
Configure the settings you have opened up to users in [Utility].
Setting | Description |
---|---|
[Level 1] | Open up the following settings to the users.
|
[Level 2] | Open up the following settings to the users.
|
[Restrict] | The settings are not opened up to users. |
To display: [Utility] - [Administrator] - [Security] - [TX Operation Log Setting]
Configure the settings to obtain logs that have the transmission history recorded. This helps to analyze a security issue if one occurs.
Setting | Description |
---|---|
[TX Operation Log Setting] | Select whether to acquire transmission logs (default: [OFF]). |
[TX Operation Log Erase] | Erases the accumulated TX operation logs. |
To display: [Utility] - [Administrator] - [Security] - [Security Details]
Restricts functions that are related to authentication operations and data management to enhance security.
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Password Rules]
To enable the password rules, set the rule level.
Regardless of which rule level you set, rules are applied to the number of characters and character types that can be used in the password.
Setting | Description |
---|---|
[Password Rules] | When enabling the Password Rules, select the rule level (default: [Disable]). Setting to [Complexity 1] applies the following rules to the password to be specified in this machine.
Setting to [Complexity 2] applies the following rules to the password to be specified in this machine.
|
[Set Minimum Password Length] | If necessary, change the minimum number of password characters (default: [15] characters). |
[Prohibited words] | Register words you want to prohibit use of when specifying a password. The banned words can be registered when [Complexity 2] is selected in [Password Rules]. |
The password rules are applied to:
Administrator Password
User Password
Account Password
User Box Password
User Box Administrator Password
Secure Print Document Password
WebDAV Server Password
SNMP Password
Remote panel server password
Encryption Passphrase
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Authentication attack detection]
Configure settings to detect signs of unauthorized accesses to this machine in an environment where user authentication is installed.
Setting | Description |
---|---|
[Password attack detection] | When enabling detection against password attacks, set this option to ON (default: OFF).
|
[Detection for authentication access attacks] | When enabling detection against authentication access attacks, set this option to ON (default: OFF).
|
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Prohibit Functions]
Define the severity of penalties applied if an incorrect password is entered during the authentication process.
Setting | Description |
---|---|
[Prohibit Functions] | Select the severity of penalties applied if an incorrect password is entered during the authentication process (default: [Mode1]).
|
[No. of Tries] | When [Mode2] is selected in [Prohibit Functions], specify the number of password entry failures that occurred until authentication operation is restricted. |
[Release] | Select an item to be released from Access Lock during authentication failure. |
[Release Time Settings] | If necessary, change the time that elapses before an access lock state in the Administrator Setting mode is canceled (default: [5] min.). If a predetermined time has elapsed after the machine was restarted, an access lock state is canceled. |
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Confidential Document Access Method]
Display the method to access files in the Secure Document User Box (default: [Mode 1]). This function is forced determined in conjunction with [Prohibit Functions].
[Mode 1]: Displays all files when the document ID and password specified in the printer driver are entered. Select a desired file and print it.
[Mode 2]: Displays all files when the document ID specified in the printer driver are entered. To print, select your desired file, then enter the appropriate password for each file.
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Manual Destination Input]
Select whether to allow the user to directly enter a destination (default: [Allow All]).
[Allow All]: Allows the direct input of destinations.
[Allow fax only]: Allows direct input of a fax number only.
[Restrict]: Restricts the direct input of destinations.
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Print Data Capture]
When allowing the user to capture print data received on this machine, set this option to ON (default: ON).
The captured data is used in order that the service engineer analyzes printer failures. For details, contact your service representative.
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Restrict Fax TX]
When prohibiting the fax transmission, set this option to ON (default: OFF).
Even if fax transmission is prohibited, fax receiving is possible.
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Address Selection Confirmation Display]
When displaying the screen to confirm the registration contents of the selected destination at selection of the registered destination, set this option to ON (default: OFF).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Personal Data Security Settings]
Set whether to hide the personal information included in job information, MIB, and notification information.
Setting | Description |
---|---|
[Job History] | Configure settings to display personal information of the job history screen.
|
[Current Job] | Configure settings to display personal information of the active job screen.
|
[Hide Personal Information] | When displaying the file name of MIB information, set this option to OFF (default: ON). |
[Withhold Personal Information] | When displaying the user name in the penalty lock notification information, set this option to OFF (default: OFF). |
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Initialize]
Initializes the settings in [Job History], [Copy Program], [Network Settings], [Store Address], and [Enhanced Server Information].
Select items you want to initialize, then tap [OK].
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Secure Print Only]
When limiting so that the machine receives only Secure Print jobs, set this option to ON (default: OFF).
Setting to ON discards print jobs other than Secure Print jobs.
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Web browser contents access]
When using the application associated with the Web browser function of this machine, select whether to allow an access to the contents saved in the storage device of this machine via the Web browser (default: [Allow]).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Export Debug Log]
When allowing the user to retrieve debug information saved in the storage device of this machine, set this option to ON (default: OFF).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Remote Service setting]
When allowing the use of the remote services, set [Allow remote service setting] to ON (default: OFF).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Web browser setting change]
Specify the type of the user who can change the user data setting of the Web browser (default: [Administrator only]).
Selecting [Administrator + User] allows you to configure the following Web browser settings using the registered user's privileges.
Home page
Start up
Web data (Cookie, Web Storage, or Indexed Database)
Authentication information
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Maintenance Mode Access]
Select whether to permit your service representative to change the settings of this machine without administrator authentication (default: [Restrict]).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Write the Configuration from USB]
When allowing the user to change the settings of this machine by loading the configuration file saved in a USB flash drive, set this option to ON (default: ON).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Storage data backup]
When allowing our service representative to back up or restore the storage on this machine, set this option to ON (default: OFF).
To display: [Utility] - [Administrator] - [Security] - [Security Details] - [Display Activity Log]
To display the communication history, set this option to ON (default: ON).
If OFF is selected, [Comm. List] does not appear on the [Job List] screen.
To display: [Utility] - [Administrator] - [Security] - [Quick Security Setting]
Summarizes settings to enhance the security of this machine. We recommend that you change settings in order to use this machine more securely.
Setting | Description |
---|---|
[Quick IP Filtering] | When using the quick IP filtering function, select the method to specify the IP address for which access is restricted. [Synchronize IP Address] is specified by default. In some areas, [No Filtering] is specified by default. |
[Administrator Password Setting] | Change the administrator password of this machine (using up to 64 single-byte characters). Be sure to remember the changed password so that you do not forget it. This setting is displayed when SSL communication is enabled in Web Connection. |
[Password Rules] | When enabling the Password Rules, select the rule level (default: [Disable]). |
[Web Conn.setting] | When using Web Connection, set this option to ON (default: ON). |
[Security Warning Display Setting] | To display the security warning screen if the administrator password remains set to the default or if password rules are not satisfied, set this option to ON. ON is specified by default. In some areas, OFF is specified by default. |
[USB flash drive function settings] | Specify whether to permit a function that requires the USB Port.
|
To display: [Utility] - [Administrator] - [Security] - [USB port connection permission setting]
Specify whether to permit a function that requires the USB Port.
Setting | Description |
---|---|
[Set All] | Select whether to restrict all the functions using the USB Port, or configure a setting for each function (default: [Detail Setting]). |
If [Detail Setting] is selected in [Set All], configure the following settings.
Setting | Description |
---|---|
[Authentication Device] | When allowing a connection with the Authentication Unit, select [Allow] (default: [Allow]). |
[External Keyboard] | When allowing the user to connect an external keyboard, set this option to ON (default: ON). |
[USB flash drive (User)] | Specify whether to allow the use of USB memory for functions to be used by the user (default: [ON]).
|
[USB flash drive (Administrator)] | Specify whether to allow the use of USB memory for functions to be used by the administrator (default: [ON]).
|
[USB flash drive (Service)] | Specify whether to allow the use of USB memory for functions to be used by the service engineer (default: [ON]).
|
[PC Connect] | Specify whether to enable to print files from a USB-connected computer (default: [ON]).
|
To display: [Utility] - [Administrator] - [Security] - [Enhanced Security Mode]
Select whether to enable the Enhanced Security Mode.
If you enable the Enhanced Security Mode, the various security functions are forcibly configured. This allows you to ensure higher-level security of data management. For details, contact your service representative.
To enable the enhanced security mode, the following settings must have been configured.
Prerequisite settings | Check Job |
---|---|
[User Auth/Account Track] - [Authentication Method] - [User Authentication] | Select an option other than [OFF]. (When external server authentication is used, only Active Directory is available as the server type.) |
[Security] - [Administrator Password Setting] | Set a password complying with password rules. |
[Security] - [Firmware Update (USB) Permission Setting] (with [Password Priority] specified) | Set a password complying with password rules. |
In Web Connection, register the certificate. | For details, refer to Encrypting Communications. |
Service settings | Service settings must be configured by your service representative. For details, contact your service representative. |
If you enable the Enhanced Security Mode, the following settings are forcibly changed.
Setting items in Administrator Settings | Settings to forcibly changed |
---|---|
[Security] - [Restrict User Access] - [Registering and changing addresses]* | Set to [Restrict]. |
[User Auth/Account Track] - [Authentication Method] - [Public User Access]* | Set to [Restrict]. |
[User Auth/Account Track] - [User Authentication Setting] - [Administrative Setting] - [User Name List]* | Set to [OFF]. |
[User Auth/Account Track] - [Print without Authentication]* | Set to [Restrict]. |
[User Auth/Account Track] - [User/Account Common Setting] - [Counter Remote Control] | Set to OFF. |
[User Auth/Account Track] - [URL display enable setting] | Set to OFF. |
[User Auth/Account Track] - [Simple Authentication setting] - [Simple Authentication setting]* | Set to OFF. |
[Network] - [FTP Setting] - [FTP Server Setting] - [FTP Server]* | Set to OFF. |
[Network] - [E-mail Setting] - [E-mail TX (SMTP)] - [Server load reduction transmission method] | When [Scan TX by Download URL method only when maximum limit is exceeded] or [Always Scan TX by Download URL method] is selected, this option is set to [OFF]. |
[Network] - [E-mail Setting] - [S/MIME] - [S/MIME Comm.Setting]* |
|
[Network] - [SNMP Setting] - [SNMP v1/v2c Setting] - [Write Community Name]* | Set to OFF. |
[Network] - [SNMP Setting] - [SNMP v3 Setting]* | [Security Level] for read and write allowed users is set to [auth-password/priv-password]. The Security Level can be changed to [auth-password]. |
[Network] - [TCP Socket Setting] - [Use SSL/TLS] | Set to ON. |
[Network] - [WebDAV Settings] - [WebDAV Server Settings] - [SSL Settings] | Set to [SSL Only]. |
[Network] - [Web Browser Setting] - [Web Browser Setting]* | Set to OFF. |
[Network] - [Remote Panel Settings]* |
|
[Network] - [E-mail Setting] - [E-mail RX Print] - [E-mail RX Print]* | Set to OFF. |
[Network] - [Machine Update Settings] - [Machine Auto Update Settings]* | This function is not available. |
[Network] - [IWS Settings] - [IWS Settings]* | Set to OFF. |
[Fax Settings] - [Report Settings] - [Tx Result Report Print Settings] - [Report File Attachment]* | Set to [Do Not Attach]. |
[Network] - [OpenAPI Setting] - [OpenAPI Setting] - [SSL/Port Settings] | Set to [SSL Only]. |
[System Settings] - [System Connection Setting] - [Mobile Connection Settings] - [Simple Connection Setting]* |
|
[Security] - [Admin. Password Change Permission Sett.] - [Allow password change] | Set to OFF. |
[Security] - [User Box Administrator Setting]* | Set to OFF. |
[Security] - [USB port connection permission setting] | Set to [Restrict]. |
[Security] - [FW Update (Network) Perm. Sett.] | Set to OFF. |
[Security] - [Secure Boot Function Set.]* | Set to ON. |
[Security] - [User box usage restriction] | If you approve the deletion of all the documents in a User Box, this option is set to [Limit]. The following User Boxes are restricted.
|
[Security] - [Security Details] - [Password Rules]* | Set to [Complexity 1]. If this option cannot be set to [Complexity 1], the enhanced security mode is not available. |
[Security] - [Security Details] - [Prohibit Functions]* |
|
[Security] - [Security Details] - [Confidential Document Access Method] | Set to [Mode 2]. |
[Security] - [Security Details] - [Print Data Capture] | Set to OFF. |
[Security] - [Security Details] - [Personal Data Security Settings] - [Hide Personal Information] | Set to ON. |
[Security] - [Security Details] - [Initialize]* | This function is not available. |
[Maintenance] - [Remote Access Setting] - [Import/Export User Data] | Set to OFF. |
[Maintenance] - [Import/Export] in Web Connection | This function is not available. |
[Security] - [PKI Settings] - [Device Certificate Setting] in Web Connection | [Remove a Certificate] is hidden. |
[Security] - [PKI Settings] - [Enable SSL Version]* | [Mode using SSL/TLS]: Set to [Admin. Mode and User Mode]. |
[Security] - [PKI Settings] - [Protocol Setting] | [Protocol 1]: [SSL], [Protocol 2]: The certificate is registered in the [HTTP Server]. |
Remote Diagnosis System | Some functions may be disabled. For details, contact your service representative. |
Preview Secure Document User Box | Only the list is displayed before the password authentication is performed. |
[Security] - [Security Details] - [Maintenance Mode Access] | Set to [Restrict]. |
Memory RX User Box | Only the administrator can print, send, or delete documents in the Memory RX User Box. |
Screen view style | Switched to the classic style. |
To display: [Utility] - [Administrator] - [Security] - [Function Management Settings]
Specify whether to use network functions for which counter management is difficult.
Setting | Description |
---|---|
[Network Function Settings] | When using the Network function, set this option to ON (default: ON). If this option is set to OFF, the following functions are not available.
|
To display: [Utility] - [Administrator] - [Security] - [Stamp Settings]
Select whether to force application of stamps to original data when printing or sending data. It is also used to delete the stamps registered on this machine.
To display: [Utility] - [Administrator] - [Security] - [Stamp Settings] - [Delete Registered Stamp]
Deletes stamps registered for Stamp, Copy Protect and Stamp Repeat.
To display: [Utility] - [Administrator] - [Security] - [Stamp Settings] - [Apply Stamps]
To forcibly apply stamps to original data when printing or sending data, set this option to ON (default: OFF). In addition, specify the stamp type, printing position, etc.
Users are not allowed to manually change or cancel the settings for the stamp function. You can explicitly indicate the sender identification by adding the user name or company name. In addition, you can use the copy security function to suppress unauthorized copy operation.
To display: [Utility] - [Administrator] - [Security] - [Firmware Update (USB) Permission Setting]
Select the method to allow the service engineer to update firmware using a USB flash drive (default: [USB port connection permission preference setting]).
[Password Priority]: Prompts the user to enter the password. Enter the required password in [Password] (using up to 20 characters). When the entered password matches the password specified here, firmware update is permitted.
[USB port connection permission preference setting]: Follows the Allow or Restrict setting that is selected in [USB flash drive (Service)] - [Firmware Update Parameters] of [Utility] - [Administrator] - [Security] - [USB port connection permission setting].
To display: [Utility] - [Administrator] - [Security] - [Driver Password Encryption Setting]
Change the encryption passphrase to encrypt authentication passwords (such as user and account passwords) when printing data using a printer driver (default: [Use Factory default settings]).
[User-Defined]: Select this option when you want to set your own encryption passphrase. Tap [Encryption Passphrase] and enter the encryption passphrase (up to 20 single-byte characters). Set the same encryption passphrase in the printer driver, too.
[Use Factory default settings]: Uses the encryption passphrase (common key) set on this machine at the time of shipping.
To display: [Utility] - [Administrator] - [Security] - [FIPS Settings]
When enabling the FIPS (Federal Information Processing Standardization) mode, set this option to ON (default: OFF).
FIPS defines security requirements for cryptographic modules. These standards have been adopted by many organizations, including U.S. federal government agencies. Enabling the FIPS Mode makes the functions of the machine conform to the FIPS.
To display: [Utility] - [Administrator] - [Security] - [TPM Setting]
Configure settings to use TPM (Trusted Platform Module).
To display: [Utility] - [Administrator] - [Security] - [TPM Setting] - [TPM Function Settings]
Select whether to enable TPM on this machine (default: [Disable]).
When TPM is enabled, enter the password required to encrypt data.
To display: [Utility] - [Administrator] - [Security] - [TPM Setting] - [TPM Key Backup]
Back up the TPM key in a USB flash drive.
In [Restoration Password], enter the password to decrypt the TPM key (using 12 to 64 single-byte characters).
To display: [Utility] - [Administrator] - [Security] - [Job Log Settings]
Configure the settings to obtain job logs.
To display: [Utility] - [Administrator] - [Security] - [Job Log Settings] - [Job Log Usage Set.]
Configure the settings to obtain job logs. After you have changed these settings, the job log is obtained when you restart this machine.
You can check usage, paper usage, operations and job history for each user or account in the job log. For details on how to viewing the output job logs, contact your service representative.
Setting | Description |
---|---|
[Enable Settings] | When obtaining job logs, set this option to ON (default: OFF). |
[Obtain Log Type] | Select whether to obtain job logs for each type.
|
[Transmission Method] | Select the method to send job logs to the server (default: [Manual (XML)]).
|
[Overwrite] | Select whether to allow the oldest job log to be overwritten by a new job log when the free space of the storage on the machine runs out (default: [Allow]). This setting is available when [Transmission Method] is set to [Manual (XML)]. |
To display: [Utility] - [Administrator] - [Security] - [Job Log Settings] - [Erase Job Log]
Delete job logs saved on this machine.
To display: [Utility] - [Administrator] - [Security] - [Job Log Settings] - [Erase job log backup]
Delete syslog-format job logs saved on this machine.
To display: [Utility] - [Administrator] - [Security] - [Job Log Settings] - [Auto Distribution Setting]
Configure a setting to automatically send job logs to the server.
Setting | Description |
---|---|
[TX Protocol] | Select the protocol used for automatic sending (default: [WebDAV]). Of the following settings, those suffixed by an asterisk "*" are only displayed when [WebDAV] is selected. |
[Host Name] | Enter the IP address or host name of the destination server. |
[File Path] | Enter the destination file path. |
[User Name] | Enter the user name used to log in to the destination server. |
[Password] | Enter the password used to log in to the destination server. |
[Port No.]* | Enter the port number for communications. |
[Proxy]* | When accessing the destination server via a proxy server, set this option to ON (default: OFF). When the destination server is accessed via a proxy server, the proxy setting configured in [Utility] - [Administrator] - [Network] - [WebDAV Settings] - [WebDAV Client Settings] is used. |
[SSL Setting]* | When accessing the destination server via SSL communication, set this option to ON (default: OFF). When the SSL communication is established, the SSL setting configured in [Utility] - [Administrator] - [Network] - [WebDAV Settings] - [WebDAV Client Settings] is used. |
[TX terms] | Specify conditions to perform the automatic sending.
|
[Send Immediately] | Immediately sends job logs. |
To display: [Utility] - [Administrator] - [Security] - [Job Log Settings] - [syslog TX settings]
Configure the setting to send job logs to the server, in the syslog format.
Setting | Description |
---|---|
[Communication Protocol] | Select the communication protocol (default: [UDP]). |
[Communication Server Settings] | Enter the IP address or host name of the destination server. |
[Port No.] | If necessary, change the port number (default: [514]). |
[Log format] | Select the log format (default: [Standard]). |
To display: [Utility] - [Administrator] - [Security] - [OpenAPI Certification Management Setting]
Specify a restriction code to prevent an OpenAPI connection application from being registered on this machine.
For details, contact your service representative.
To display: [Utility] - [Administrator] - [Security] - [Virus scan settings]
Configure settings to perform virus scanning for data that is transferred between this machine and external environment such as a cloud service, computer, or USB flash drive.
Setting | Description |
---|---|
[Real-time scan] | When executing virus scanning when data is being sent or received, set this option to ON (default: OFF). Also, set the restriction level for jobs that can be executed on this machine when a virus is detected (default: [Level 1: Delete transmission jobs only.]). |
[Manual scan] | Executes virus scanning at the desired timing. To execute manual scan, you need to set [Regular Scan settings] to ON in [Regular scan]. |
[Regular scan] | When periodically executing virus scanning, set this option to ON (default: OFF). Also, set the virus scanning schedule.
|
[Risk log] | Displays the virus detection history. To print out the histories, tap [Print], select the paper tray and print side, and execute printing. To confirm the history details, select the target history, and tap [Detail]. |
[Scan log] | Displays the execution histories as the regular scan and manual scan results. To print out the execution histories, tap [Print], select the paper tray and print side, and execute printing. |
[Version Information] | Displays the virus scan engine, the pattern file version, and the last update date of the pattern file. Also, set whether to display a warning message on the screen when a pattern file update fails. When displaying the warning message, set [Update failure of pattern file] to ON (default: ON). |
To display: [Utility] - [Administrator] - [Security] - [FW Update (Network) Perm. Sett.]
Select whether to allow the firmware update via the network (default: [Allow]).
To display: [Utility] - [Administrator] - [Security] - [Secure Boot Function Set.]
Select whether to enable the secure boot function (default: OFF).
To display: [Utility] - [Administrator] - [Security] - [User box usage restriction]
Specify whether to restrict the use of various User Boxes for each User Box.