Home Settings and AdjustmentsDensity Balance Adjustment (Adjustment Flow When Changing the Screen)

Density Balance Adjustment (Adjustment Flow When Changing the Screen)

This measures the output chart using a spectrophotometer, and automatically correct the density balance according to the feedback of the measurement result.

Perform the following three processes in the order indicated:

STEP 1: Measure the density balance using a spectrophotometer.

Arrow

STEP 2: Save the measured data of the density balance.

Arrow

STEP 3: Register the adjusted value of the density balance in the machine.

• Image quality adjustment flow and the position of this adjustment

  • In the pre-output image quality adjustment flow, this adjustment is positioned shown below.

  • Perform the previous adjustment before proceeding with this adjustment.

  • When Intelligent Quality Optimizer IQ-501 is mounted on the machine, this adjustment is positioned in the same way as the above.

- For Image Controller IC-603:

Image quality adjustment flow

Position of this adjustment

Previous adjustment

This adjustment

Next adjustment

Adjustment flow when changing the screen

Without RU

(STEP 2: Gamma automatic adjustment)

STEP 3: This adjustment

(STEP 4: Calibration)

With RU

(STEP 2: Gamma automatic adjustment)

STEP 3: This adjustment

(STEP 4: Color density control)

Regular adjustment flow (Standard)

Without RU

- (None)

With RU

Regular adjustment flow (High accuracy)

Without RU

- (None)

With RU

- For Image Controller IC-417 or Image Controller IC-313:

Image quality adjustment flow

Position of this adjustment

Previous adjustment

This adjustment

Next adjustment

Adjustment flow when changing the screen

Without RU

- (None)

STEP 3: This adjustment

(STEP 4: Calibration)

With RU

(STEP 2: Gamma automatic adjustment)

STEP 3: This adjustment

(STEP 4: Color density control)

Regular adjustment flow (High accuracy)

Without RU

- (None)

With RU

- (None)

Measuring the density balance using a spectrophotometer

When Intelligent Quality Optimizer IQ-501 is not mounted on this machine, chart color measurement is required in the external spectrophotometer (i1-Pro, i1-Pro2 and i1-iSisXL, or FD-5 BT and FD-9).

Also, the dedicated application is required to measure test charts. The application varies depending on your spectrophotometer. For i1-Pro/i1-Pro2 and i1-iSisXL, use X-rite Measure Tool. For FD-5 BT and FD-9, use FD-S2w. Install the tool in advance.

  • You can download X-rite Measure Tool free of charge at the following Web site. After installing the tool, restart the computer.
    ProfileMaker 5 v5.0.10
    https://xritephoto.com/ph_product_overview.aspx?ID=757&Action=Support&SoftwareID=931

  • To use the spectrophotometer, i1iSis, perform Step 10 (select [Measure] from the menu) followed by the procedure of "• For the spectrophotometer, i1iSis."

  • To use FD-5 BT or FD-9, use FD-S2w. For details on operations, refer to the user's guide supplied with FD-S2w. When FD-9 is used as the spectrophotometer, test charts with QR code are printed out. Measuring test charts with QR code allows you to select a definition chart on FD-S2w and automatically input chart numbers and printer information to the machine, thereby, helping ensure efficient input work.

  1. On the control panel of the main body, press Utility/Counter.

    The [UTILITY] screen is displayed.

  2. Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence.

  3. Press [Density Balance Chart Output].

  4. Select the chart to be output according to the spectrophotometer to be used.

    After the selection, press [Print Mode].

    The recommended charts are as follows.

    - [Type 1] of [<Measure Spectrophotometer-1 (FD-9)>]

    - [Type 1] of [<Measure Spectrophotometer-1 (i1-iSisXL)>]

    - [Type 2] of [<Measure Spectrophotometer-2 (i1-Pro/i1-Pro2)>]

    - [Type 3] of [<Measure Spectrophotometer-3 (FD-5 BT)>]

    Item

    Description

    [<Measure Spectrophotometer-1 (FD-9)>]

    [Type 1]

    Simple checking chart for 8-step gradation (Recommended)

    [Type 2]

    Detailed checking chart for 16-step gradation

    [<Measure Spectrophotometer-1 (i1-iSisXL)>]

    [Type 1]

    Simple checking chart for 8-step gradation (Recommended)

    [Type 2]

    Detailed checking chart for 16-step gradation

    [<Measure Spectrophotometer-2 (i1-Pro/i1-Pro2)>]

    [Type 1]

    Simple checking chart for 1-step gradation

    [Type 2]

    Detailed checking chart for 3-step gradation (Recommended)

    [<Measure Spectrophotometer-3 (FD-5 BT)>]

    [Type 1]

    Simple checking chart for 1-step gradation (Spot measurement)

    [Type 2]

    Detailed checking chart for 3-step gradation (Spot measurement)

    [Type 3]

    Detailed checking chart for 3-step gradation (Strip measurement)

    • When spectrophotometer-1 (FD-9) is used for measurement, test charts with QR code can be printed out for both [Type 1] and [Type 2]. Measuring test charts with QR code allows you to automatically input information such as chart numbers to the machine.

  5. Set the paper on the [PRINT MODE] screen and press Start on the control panel.

    The color chart is output for measurement using the spectrophotometer.

    • To use FD-5 BT or FD-9, use FD-S2w. For details on operations, refer to the user's guide supplied with FD-S2w.

  6. On the computer where the X-rite Measure tool has been installed, select [Start] - [All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].

    X-rite Measure tool starts.

    • To change the language, select a language in [Language] and then restart Measure Tool.

  7. When the following message is displayed, click [OK].

  8. Connect the instrument to the computer. From the menu, click [Configuring].

    The [Instrument Configuration] screen is displayed.

  9. In [Instrument], select the spectrophotometer to use. When [OK] is displayed, close the screen.

    Example: This example selects [Eye-One Pro] (i1Pro).

  10. From the menu, click [Measuring].

    • The subsequent operations are described for the case where the spectrophotometer i1Pro is used. For measurement using the spectrophotometer i1iSis, refer to "• For the spectrophotometer i1iSis."

  11. From [Test Chart], select [Custom].

  12. Specify [Columns] and [Rows], and click [OK].

    • When the spectrophotometer is "Type 1" of i1Pro: [Columns] = 6, [Rows] = 5

    • When the spectrophotometer is "Type 2" of i1Pro: [Columns] = 6, [Rows] = 13

  13. Click [Start].

  14. When the following message is displayed, horizontally place the spectrophotometer on the calibration dock and click [OK].

  15. Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it.

    • To eliminate the influence of the color of the table, place 10 sheets of paper of the same type as the chart underneath the chart to be measured.

  16. When the following screen is displayed, place the spectrophotometer on the patch at the top in the upper left, and press the button for the spectrophotometer. When beep sounds, check that the read patch is displayed on the screen.

  17. Continuously, place the spectrophotometer on the next right patch, and press the button for the spectrophotometer. Measure all the patches in the same operation.

    • If you place the spectrophotometer on the wrong place (patch), click the  button to go back to the previous patch position.

    • The white portion where it is displayed that nothing is printed is also part of the patch. Do not forget to measure it. If not measured, an error will occur.

  18. When you are finished with the chart measurement, click [Close].

    • Continuously, go to "Saving the measured data of the density balance," and save the measurement data.

• For the spectrophotometer i1iSis

To use the spectrophotometer i1iSis, perform Step 10 (from the menu, select [Measure]) followed by the procedure below.

  1. From [Test Chart], select [Open].

  2. Select the script data for measurement according to the paper size, and click [Open].

    There are some script data items particular for each chart size or type. For details, contact your service representative.

  3. On the following screen, click [Start].

  4. When the following message is displayed, insert the chart into i1isis.

    • Cut off the left side of the chart using scissors or such other tools so that the length between the left end of the chart and the black diamond symbol (◆) becomes about 10 mm.

    • Align the left end of the paper to the left end of the insert opening of i1isis, and automatically feed the paper one by one. When correctly inserted, the chart is pulled in a few centimeters and comes back a little, and then after a little while, reading starts.

    Measurement automatically starts.

Saving the measured data of the density balance

You can save the data of the density balance measured with the spectrophotometer to a USB device such as a USB memory stick or to the computer on the network used by the machine.

  1. From the [File] menu, select [Save As].

    If you use [Export Lab], an error occurs when registering the color adjustment data. When saving the data, always use [Save As].

  2. Specify the destination to save.

    Specify USB memory or the computer connected to the machine via the network.

    Stored

    Description

    USB Memory

    Connect the USB memory to the computer.

    Create a folder, "\C2070\ADJUST _DATA," in the root (immediately below) of the USB memory, and specify the place as the destination to save.

    Computer on the network

    Open the computer connected to the network used by the machine, and specify a desired folder.

  3. Enter the file name to save the measured data and click [Save].

    • Specify the "14-character identification number printed on the chart" + "_" (underscore) + "character string of up to 21 characters."

    Example: 2021115011C4CC_i1pro_2012-10-15.txt

    The measured data of the density balance is saved.

Registering the adjusted value of the density balance in the machine

You can register the measured data (adjusted value of the density balance) saved in the USB memory or the computer on the network in the machine.

Place to save measured data

Operation

Measured data saved in the USB memory

Connect the USB memory device and register the data using the control panel of the main body.

Refer to "• Registering the measured data saved in the USB memory."

Measured data saved in the computer on the network

Send (upload) the measured data using Web Utilities from the Web browser and then register the data. For details about Web Utilities, refer to Overview of Web Utilities.

Refer to "• Registering the measured data saved in the computer on the network."

• Registering the measured data saved in the USB memory

  1. On the control panel of the main body, press Utility/Counter.

    The [UTILITY] screen is displayed.

  2. Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence.

  3. Press [Density Balance Data Reg/Del].

  4. Select the number where the adjusted value is to be registered and press [USB Memory].

    • If you select the registered number, the adjusted value is overwritten.

  5. The following screen is displayed. Connect the USB memory where the measured data has been saved to the main body, and press [OK].

  6. Select the file name of the measured data to be registered and press [OK].

  7. When the following screen is displayed, press [OK].

    The adjusted value of the density balance is registered.

• Registering the measured data saved in the computer on the network

  1. On the computer on the network where the measured data has been saved, open a Web browser.

    • It is recommended that you log in to Web Utilities from the computer where the measured data has been saved.

  2. In the URL field, enter "http://IP address of the machine (or the host name):30091" and press the Enter key.

    • If the controller of EFI is implemented, ":30091" at the end of the IP address is unnecessary.

    The main page of the Web Utilities is displayed.

  3. Click on [Machine Manager Setting].

  4. Enter the [User Name] and [Password] and click [OK].

  5. Click on [Color Measuring data Input].

  6. Specify the [File Name] and [File Path] and click [Upload].

    • Enter the file name (Example: 2021115011C4CC_i1pro_2012-10-15.txt).

    • Click [Reference] of the [File Path] and select the measured data saved in the computer.

  7. On the control panel of the main body, press Utility/Counter.

    The [UTILITY] screen is displayed.

  8. Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence.

  9. Press [Density Balance Data Reg/Del].

  10. Select the number where the adjusted value is to be registered and press [Archived Data].

    • If you select the registered number, the adjusted value is overwritten.

  11. Select the file name of the measured data to be registered and press [OK].

  12. When the following screen is displayed, press [OK].

    The adjusted value of the density balance is registered.