Configuring the TWAIN scan environment

Setting flow

Using the TWAIN driver enables you to use this machine as a scanner by controlling it from a computer connected to the network.

When using the TWAIN scan, follow the below procedure to configure the settings.

  1. Configuring network settings of this machine ( [Network Settings] )

  2. Configuring basic settings for TWAIN Scan ( [Configuring the basic settings for the TWAIN scan] )

  3. Configuring settings to suit your environment

    supplementary explanationChanging the operation lock time ( [Changing the operation lock time] )

Configuring the basic settings for the TWAIN scan

Configure the settings to use the TWAIN Scan function.

  1. Select [Network] - [SNMP Setting] in administrator mode of Web Connection (or in [Utility] - [Administrator] of this machine), and configure the following settings.

    Setting

    Description

    [SNMP]

    When using the TWAIN scan function, set this option to ON (default: ON). Select the check box of the SNMP version you use.

    [UDP Port Setting]

    If necessary, change the UDP port number (default: [161]).

  2. Select [Network] - [TCP Socket Setting] in administrator mode of Web Connection (or in [Utility] - [Administrator] of this machine), and configure the following settings.

    Setting

    Description

    [TCP Socket]

    When using the TWAIN scan function, set this option to ON (default: ON).

    [Port No.]

    If necessary, change the TCP Socket port number (default: [59158]).

Changing the operation lock time

While the TWAIN scan is running, Control Panel operations are locked. If necessary, change the time period before the control panel is unlocked.

Select [System Settings] - [Network TWAIN] in user mode of Web Connection (or in [Utility] - [Utility] of this machine), and configure the following settings.

Setting

Description

[TWAIN Lock Time]

Change the time until the operation lock is released (default: [120] seconds).