Home Settings and AdjustmentsImage Quality Adjustment Flow of Image Controller IC-603

Image Quality Adjustment Flow of Image Controller IC-603

To reproduce stable colors, adjust the image quality.

This section describes flows for Image Controller IC-603.

These flows are available:

  • Adjustment flow when changing the screen

  • Regular adjustment flow (Standard)

  • Regular adjustment flow (High accuracy)

Items to be adjusted differ depending on whether the RU option is used or not.

Adjustment Flow when changing the screen

When changing the screen, perform the following image quality adjustment.

  • This adjustment is the same as the adjustment when the machine was introduced (setup).

  • If you use Package Color Auto Adj., this machine automatically makes the adjustments in step 2 below and after. To use the function, install Integrated Color Care Unit IQ-501. For details, refer to Package Color Auto Adj..

• Without the RU option (Relay Unit RU-509)

STEP 1: Screen selection

In response to the setting (assignment) change of the screen, select the screen to be used.

Screen Selection (Adjustment Flow When Changing the Screen)

Arrow

STEP 2: Gamma automatic adjustment

This automatically adjusts the color reproducibility of the whole paper to be output.

Gamma Automatic Adjustment (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (High Accuracy))

Arrow

STEP 3: Density balance adjustment

This machine automatically adjusts the density balance.

Density Balance Adjustment (Adjustment Flow When Changing the Screen)

ArrowArrow

• With the RU option (Relay Unit RU-509)

STEP 1: Screen selection

In response to the setting (assignment) change of the screen, select the screen to be used.

Screen Selection (Adjustment Flow When Changing the Screen)

Arrow

STEP 2: Gamma automatic adjustment

This automatically adjusts the color reproducibility of the whole paper to be output.

Gamma Automatic Adjustment (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (High Accuracy))

Arrow

STEP 3: Density balance adjustment

This machine automatically adjusts the density balance.

Density Balance Adjustment (Adjustment Flow When Changing the Screen)

Arrow

STEP 4: Color density control

Set the [Periodical Adj. Execution] of [Basic Setting] to [ON], and perform [Color Density Manual Control] as needed.

Color Density Control (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (Standard) / Regular Adjustment Flow (High Accuracy))

To use special paper or increase the accuracy of the automatic adjustment, [Each Paper Type Color Adj.] is recommended. For details, refer to Color Density Control (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (Standard) / Regular Adjustment Flow (High Accuracy)).

Arrow

Regular adjustment flow (Standard)

This adjustment is recommended for all customers in their daily operations.

Perform this adjustment at any of the following timings:

  • When between 1,000 and 2,000 sheets of paper have been output

  • Immediately before the job for which hue is important is output

  • Others, such as when you cannot get the desired hue

• Without the RU option (Relay Unit RU-509)

• With the RU option (Relay Unit RU-509)

Check that the RU option is used.

When the RU option is used, calibration is automatically executed.

Regular adjustment flow (High accuracy)

In addition to "Regular adjustment flow (Standard)," perform this adjustment especially in the following cases:

  • Immediately before the job for which hue is important is output

  • When the color stability is not desirable (you want to increase the accuracy of reproducibility)

  • When the paper type is different

If you use Package Color Auto Adj., this machine automatically makes the adjustments in step 2 below and after. To use the function, install Integrated Color Care Unit IQ-501. For details, refer to Package Color Auto Adj..

• Without the RU option (Relay Unit RU-509)

STEP 1: Gamma automatic adjustment

This automatically adjusts the color reproducibility of the whole paper to be output.

Gamma Automatic Adjustment (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (High Accuracy))

Arrow

STEP 2: Maximum density adjustment

Increase the accuracy of reproducibility of density.

Maximum Density Adjustment (Regular Adjustment Flow (High Accuracy))

Arrow

• With the RU option (Relay Unit RU-509)

STEP1: Color density control

In [Color Density] in [Paper Setting], check if [Default Adj. Data] or [Registered Adj. Data] is selected for the tray.

Color Density Control (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (Standard) / Regular Adjustment Flow (High Accuracy))

To use general paper, select [Default Adj. Data].

To use special paper or increase the accuracy of the automatic adjustment, [Each Paper Type Color Adj.] is recommended. For details, refer to Color Density Control (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (Standard) / Regular Adjustment Flow (High Accuracy)).

Arrow

STEP 2: Gamma automatic adjustment

This automatically adjusts the color reproducibility of the whole paper to be output.

Gamma Automatic Adjustment (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (High Accuracy))

Arrow

STEP 3: Maximum density adjustment

Increase the accuracy of reproducibility of density.

Maximum Density Adjustment (Regular Adjustment Flow (High Accuracy))

Arrow