The media does not rotate well.

Roll Winder RW-101

If the rotation of the media set on the feeding shaft is not stable, check the following.

Symptom

Remedy

The feeding shaft rotates but much paper dust is generated around the lug or feeding shaft.

Tighten the lug protruding/retracting handle.

If the media core is damaged, dispose of the media core after the roll end is detected. If you have another winder, rewind the media using a new media core.

The rotation of the media is unstable only during the slow conveyance before starting printing.

Increase the tension value (kgf) on the touch panel of Roll Winder RW-201 ([Menu] screen - [1,Wind/2,Paper feed] - [2]).

Roll Winder RW-201

If the rotation of the media set on the winding shaft is not stable, check the following.

Symptom

Remedy

The winding shaft rotates but much paper dust is generated around the lug or winding shaft.

Tighten the lug protruding/retracting handle.

If the media core is damaged, replace it with a new one.

The rotation of the media is unstable only during the slow conveyance before starting printing.

Increase the tension value (kgf) on the touch panel of Roll Winder RW-201 ([Menu] screen - [1,Wind/2,Paper feed] - [1]).