This measures the output chart using a spectrophotometer, and automatically correct the density balance according to the feedback of the measurement result.
Perform the following three processes in the order indicated:
• Image quality adjustment flow and the position of this adjustment
In the pre-output image quality adjustment flow, this adjustment is positioned shown below.
Perform the previous adjustment before proceeding with this adjustment.
To not continuously perform the series of adjustment of the image quality adjustment flow, perform Gamma Automatic Adjustment (Adjustment Flow When Changing the Screen / Regular Adjustment Flow (High Accuracy)), and then resume from the next adjustment.
• For Image Controller IC-602:
Image quality adjustment flow | Position of this adjustment | ||
Previous adjustment | This adjustment | Next adjustment | |
Adjustment flow when changing the screen | (STEP 2: Gamma automatic adjustment) | STEP 3: This adjustment | (STEP 4: Color density control) |
Regular adjustment flow (Standard) | - (None) | ||
Regular adjustment flow (High accuracy) | - (None) |
• For Image Controller IC-308 or Image Controller IC-310:
Image quality adjustment flow | Position of this adjustment | ||
Previous adjustment | This adjustment | Next adjustment | |
Adjustment flow when changing the screen | (STEP 2: Gamma automatic adjustment) | STEP 3: This adjustment | (STEP 4: Color density control) |
Regular adjustment flow (High accuracy) | - (None) |
To measure the chart, use the X-rite Measure tool (for the spectrophotometer i1iSis or i1Pro) or Color Care measure (for the spectrophotometer FD-5 BT). Install the tool in advance.
You can download the X-rite Measure tool free of charge at the following Web site. After installing the tool, restart the computer.
ProfileMaker 5 v5.0.10:
http://www.xrite.com
To use the spectrophotometer i1iSis, perform Step 10 (select [Measure] from the menu) followed by the procedure of "• For the spectrophotometer i1iSis."
To use the spectrophotometer FD-5 BT, perform Step 5 (output the color chart) followed by the procedure of "• For the spectrophotometer FD-5 BT."
On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen.
The [Adjustment Menu] is displayed.
Press [Density Balance Adjustment] on the [Adjustment Menu] screen.
Press [Density Balance Chart Output].
Select the chart to be output according to the spectrophotometer (i1iSis/i1Pro/FD-5 BT) to be used.
After the selection, press [Print Mode].
The [Type1] of [<Measure Spectrophotometer-1 (i1-iSis)>], the [Type2] of [<Measure Spectrophotometer-2 (i1-Pro)>], or the [Type3] of [<Measure Spectrophotometer-3 (FD-5 BT)>] is recommended.
Item | Description | |
---|---|---|
[<Measure Spectrophotometer-1 (i1-iSis)>] | [Type 1] | Simple checking chart for 8-step gradation (Recommended) |
[Type 2] | Detailed checking chart for 16-step gradation | |
[<Measure Spectrophotometer-2 (i1-Pro)>] | [Type 1] | Simple checking chart for 1-step gradation |
[Type 2] | Detailed checking chart for 3-step gradation (Recommended) | |
[<Measure Spectrophotometer-3 (FD-5 BT)>] | [Type 1] | Simple checking chart for 1-step gradation (Spot measurement) |
[Type 2] | Detailed checking chart for 3-step gradation (Spot measurement) | |
[Type 3] | Detailed checking chart for 3-step gradation (Strip measurement) |
Set the paper on the [PRINT MODE] screen and press Start on the control panel.
The color chart is output for measurement using the spectrophotometer.
On the computer where the X-rite Measure tool has been installed, select [Start] - [All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].
X-rite Measure tool starts.
The following description uses screen examples in English. To change the display language for the menu and messages, select the language from [Language] on the [Measure Tool] toolbar, and then restart the X-rite Measure tool.
When using the spectrophotometer FD-5 BT, perform the measurement on the computer installed with Color Care measure. For the subsequent procedure, refer to "• For the spectrophotometer FD-5 BT."
When the following message is displayed, click [OK].
Connect the instrument to the computer. From the menu, click [Configuring].
The [Instrument Configuration] screen is displayed.
In [Instrument], select the spectrophotometer to use. When [OK] is displayed, close the screen.
Example: This example selects [Eye-One Pro] (i1Pro).
From the menu, click [Measuring].
The subsequent operations are described for the case where the spectrophotometer i1Pro is used. For measurement using the spectrophotometer i1iSis, refer to "• For the spectrophotometer i1Sis."
From [Test Chart], select [Custom].
Specify [Columns] and [Rows], and click [OK].
When the spectrophotometer is "Type 1" of i1Pro: [Columns] = 6, [Rows] = 5
When the spectrophotometer is "Type 2" of i1Pro: [Columns] = 6, [Rows] = 13
Click [Start].
When the following message is displayed, horizontally place the spectrophotometer on the calibration dock and click [OK].
Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it.
To eliminate the influence of the color of the table, place 10 sheets of paper of the same type as the chart underneath the chart to be measured.
When the following screen is displayed, place the spectrophotometer on the patch at the top in the upper left, and press the button for the spectrophotometer. When beep sounds, check that the read patch is displayed on the screen.
Continuously, place the spectrophotometer on the next right patch, and press the button for the spectrophotometer. Measure all the patches in the same operation.
If you place the spectrophotometer on the wrong place (patch), click the button to go back to the previous patch position.
The white portion where it is displayed that nothing is printed is also part of the patch. Do not forget to measure it. If not measured, an error will occur.
When you are finished with the chart measurement, click [Close].
Continuously, go to "Saving the measured data of the density balance," and save the measurement data.
• For the spectrophotometer i1iSis
To use the spectrophotometer i1iSis, perform Step 10 (from the menu, select [Measure]) followed by the procedure below.
From [Test Chart], select [Open].
Select the script data for measurement according to the paper size, and click [Open].
For details about the script data, contact your service representative.
• Denbal1117V01.txt: Data for the paper of 11 17 inches
• Denbal1218V01.txt: Data for the paper of 12 18 inches
• Denbal1319V01.txt: Data for the paper of 13 19 inches
• DenbalA3V01.txt: Data for the A3 paper
• DenbalSRA3V01.txt: Data for the SRA3 paper
On the following screen, click [Start].
When the following message is displayed, insert the chart into i1iSis.
Cut off the left side of the chart using scissors or such other tools so that the length between the left end of the chart and the black diamond symbol (♦) becomes about 10 mm.
Align the left end of the paper to the left end of the insert opening of i1iSis, and automatically feed the paper one by one. When correctly inserted, the chart is pulled in a few centimeters and comes back a little, and then after a little while, reading starts.
Measurement automatically starts.
• For the spectrophotometer FD-5 BT
For the spectrophotometer FD-5 BT, use Color Care measure.
To use Color Care measure, you need to acquire a license key. For details, refer to the user's guide that comes with Color Care measure.
On the Color Care measure screen, select a chart based on the number of color chips. You should select the one having the same number of rows and columns of color chips printed on it.
When measuring a chart for the spot measurement (Type 1, Type 2), select a chip to be measured first (upper right) before starting the operation.
When measuring a chart for the strip measurement (Type 3), you can directly start the operation.
When you use Color Care measure to register data through the Web, a password entry is requested. Enter the administrator password registered on the machine.
You are also asked to enter 14 characters of identifying information printed on the chart and the IP address for the machine.
You can save the data of the density balance measured with the spectrophotometer to a USB device such as a USB memory stick or to the computer on the network used by the machine.
From the [File] menu, select [Save As].
If you use [Export Lab], an error occurs when registering the color adjustment data. When saving the data, always use [Save As].
Specify the destination to save.
Specify USB memory or the computer connected to the machine via the network.
Destination to save | Description |
---|---|
USB Memory | Connect the USB memory to the computer. Create a folder, "\C1100\ADJUST_DATA," in the root (immediately below) of the USB memory, and specify the place as the destination to save. |
Computer on the network | Open the computer connected to the network used by the machine, and specify a desired folder. |
Enter the file name to save the measured data and click [Save].
Specify the "14-character identification number printed on the chart" + "_" (underscore) + "character string of up to 21 characters."
Example: 2021115011C4CC_i1pro_2012-10-15.txt
The measured data of the density balance is saved.
You can register the measured data (adjusted value of the density balance) saved in the USB memory or the computer on the network in the machine.
Place to save measured data | Operation |
---|---|
Measured data saved in the USB memory | Connect the USB memory and register the data using the touch panel of the main body. Refer to "• Registering the measured data saved in the USB memory." |
Measured data saved in the computer on the network | Send (upload) the measured data using Web Utilities from the Web browser and then register the data. For details about Web Utilities, refer to Overview of Web Utilities. Refer to "• Registering the measured data saved in the computer on the network." |
• Registering the measured data saved in the USB memory
On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen.
The [Adjustment Menu] is displayed.
Press [Density Balance Adjustment] on the [Adjustment Menu] screen.
Press [Density Balance Data Reg/Del].
Select the number where the adjusted value is to be registered and press [USB Memory].
If you select the registered number, the adjusted value is overwritten.
The following screen is displayed. Connect the USB memory where the measured data has been saved to the main body, and press [OK].
Select the file name of the measured data to be registered and press [OK].
When the following screen is displayed, press [OK].
The adjusted value of the density balance is registered.
• Registering the measured data saved in the computer on the network
On the computer on the network where the measured data has been saved, open a Web browser.
It is recommended that you log in to Web Utilities from the computer where the measured data has been saved.
In the URL field, enter "http://IP address of the machine (or the host name):30091" and press the Enter key.
If the controller of EFI is implemented, ":30091" at the end of the IP address is unnecessary.
The main page of the Web Utilities is displayed.
Click on [Machine Manager Setting].
Enter the [User Name] and [Password] and click [OK].
Click on [Color Measuring data Input].
Specify the [File Name] and [File Path] and click [Upload].
Enter the file name (Example: 2021115011C4CC_i1pro_2012-10-15.txt).
Click [Reference] of the [File Path] and select the measured data saved in the computer.
On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen, and then press [Density Balance Adjustment] on the [Adjustment Menu] screen.
Refer to Steps 1 and 2 of "• Registering the measured data saved in the USB memory."
Press [Density Balance Data Reg/Del].
Select the number where the adjusted value is to be registered and press [Archived Data].
If you select the registered number, the adjusted value is overwritten.
Select the file name of the measured data to be registered and press [OK].
When the following screen is displayed, press [OK].
The adjusted value of the density balance is registered.