* Enter the name of the utility key. You can search descriptions of utility keys.

Line Detection

To display: [Utility][Expert Adjustment][Line Detection]

Set this option for the dirt detection level for the Slit Scan Glass and cleaning of the Slit Scan Glass.

Setting

Description

[Prior Detection Setting]

When detecting dirt on the Slit Scan Glass in advance, set this option to ON (default: ON).

  • [Warning Display]: Select the type of warning messages to be displayed on the screen of this machine (default: [TYPE1]).
    [TYPE1]: Shows a warning icon in the icon display area.
    [TYPE2]: Shows a warning message in the message display area.
    [TYPE3]: Shows a warning message on the entire screen.

  • [Detection level]: Select a contamination detection level (default: [Std.]).
    [Low]: Makes it harder to detect contamination.
    [Std.]: Detects contamination at an ordinary level.
    [High]: Makes it easy to detect contamination.

[Feed Cleaning Settings]

To clean the Slit Scan Glass when scanning an original in the ADF, set this option to ON (default: ON).