On the measurement screen, select a colorimeter and then start measurement.
To measure a chart, install the driver of your colorimeter.
For details, refer to its manual.
Patterns of charts and available sizes of paper vary among types of colorimeters.
According to the colorimeter, operations differ. For details, refer to its manual.
Select a colorimeter from [Instrument] on the chart measurement screen.
According to the selection, the chart image appears on the upper-right of the screen.
[i1iSis (UV Filer)] returns the measurement result with the UV cut filter.
Specify the copy number of the chart outputting to [Copies].
Click [Output] to print the chart.
Before you print the chart, perform calibration.
For details, refer to Calibration.
Click [Start] to start the measurement.
An operation screen for the colorimeter appears. Follow the instructions on the windows that follow.
The current position of measurement appears on the chart image of the upper-right of the screen.
If you measure a wrong line, a warning message appears. You can select either to try again with the correct line or to proceed to the next line.
To stop the measurement, click [Stop].
After the acquirement of measurement data, [Save the Result] becomes available.
The value of each patch appears in the measurement result list.
Click [Save the Result] after completing the measurement.
[Save As] screen appears.
Specify the saving place and file name, and click [Save].
Returns to the Chart Measurement screen after saving the measurement result file.
Click [Next].
The UCR/GCR Setting screen appears.