Adjust the magnification in paper feed direction when scanning the original from the original glass.
Make this adjustment after completing [Machine Adjustment] - [Printer Adjustment] - [CD-Mag. Adjustment].
Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.
Press [Machine Adjustment], [Scan Adjustment], and [CD-Mag. Adjustment] in sequence.
Press [Print Mode].
Load A3 paper or 11 17 paper, then select that tray.
Position the test chart on the original glass, then press Start on the control panel.
A sample pattern will be output.
Check the misalignment by comparing the original and the output.
Measure the error of the width A on the chart and the width A on the test print.
Allowance: Within ± 1 mm
If any adjustment is required, press [Exit PrintMode] to return to the [CD-Mag. Adjustment] screen.
Use the touch panel keypad or the keypad on the control panel to enter the setting data.
Use [+/-] to specify the value to be positive or negative.
Press [Set] to change the current value.
Adjustment Range: 990 ([Short]) to 1010 ([Long]) (1 step = 0.001)
Repeat steps 3 to 8 until the desired result is obtained.
Press [Return].
The screen returns to the [Scan Adjustment Menu] screen.