Home Machine InformationProcedure of Both Sides Adjust

Procedure of [Both Sides Adjust]

The following shows the procedure for the [Both Sides Adjust].

  1. Checking the reference position of the printing side .

    To determine the misalignment of printing position, the adjustment of the reference position required on the main body side must be completed.

    Before performing the [Both Sides Adjust], check the adjusted value of the reference position and make adjustment as needed.

    The following items of [Adjustment] - [Machine Adjustment] - [Printer Adjustment] on the [MACHINE] screen are adjustment items that need to be checked:

    Adjust the front side in the following order, and then adjust the back side in the same order.

    [ FD-Mag. Adjustment] - [CD-Mag. Adjustment] - [Restart Timing Adjustment] - [Centering Adjustment]

    • The adjustment for the reference position of the print side is an advanced adjustment. Contact your service representative in advance of the adjustment.

  2. Performing [Both Sides Adjustment] per Tray.

    The adjustment can be made by either of the following four methods:

    • [Scan Meas.] adjustment: the method used for scanning both sides of an adjustment chart using the scanner functions of this machine and automatically making both side adjustment.->Scan Meas. adjustment

    • [Scan Meas.] requires the front-side adjustment depending on the firmware version. For details, contact your service representative.

    • [Gap] adjustment: the method used for aligning both sides with correction of the back side magnification and print position based on the front side ones.->Gap adjustment

    • [Chart Adjustment]: the method used for aligning both sides with correction of the magnification and print position of both front and back side.->Chart Adjustment

    • [Zoom]/[Image Shift] adjustment: the method used for fine adjustment after [Scan Meas.] adjustment, [Gap] adjustment, or [Chart Adjustment], or the method used when the amount of misalignment between both sides is figured out.->Zoom/Image Shift Adjustment

    You need not perform both of the [Scan Meas.] and [Gap] adjustment.

    You can change the default screen of the [Both Sides Adjust] screen. For details, contact your service representative.

  • If the paper is bent or wrinkled when printing, adjust the [Registration Loop] amount before performing [Scan Meas.] adjustment, [Gap] adjustment, [Chart Adjustment] or the [Zoom]/[Image Shift] adjustment. For details, refer to Adjustment of Registration Loop.