Home Settings and AdjustmentsFD-Mag. Auto Adjustment: Automatically Adjusting FD-Mag. When scanning on the ADF

FD-Mag. Auto Adjustment: Automatically Adjusting FD-Mag. When scanning on the ADF

Adjust the magnification in paper feed direction when scanning on the ADF

  1. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.

  2. Press [ADF Adjustment] and [FD-Mag. Auto Adjustment] in sequence.

  3. Place the test chart on the ADF tray, and press [Start].

    • Face the test chart surface upward and place it in the ADF tray.

  4. Automatic adjustment is performed, and its result is displayed.

    • If it ends successfully, [Adjustment Result] indicates [OK]. If it ends abnormally, [NG] is displayed. Adjust it using the [FD-Mag. Adjustment].

  5. Make sure that the adjustment result is [OK], and press [Set].

    • The [Magnification Adj.(%)] value is reflected on [Current Data].

  6. Press [Return].

    The screen returns to the [ADF Adjustment Menu] screen.