Control the condition of glue to be dried by setting temperature on the sensors inside the melt tank and of the glue apply roller using Perfect Binder PB-503.
The following two types of sensors are provided.
Glue Tank -Low:
Adjust the temperature to control the tank heater.
Low temperature: increases glue viscosity, High temperature: decreases glue viscosity
Initial: 185°C
Recommended: 180 °C to 190 °C
Glue Apply Roller:
Adjust the temperature to control the roller heater. This also supports heating of the glue.
Low temperature: increases glue viscosity, High temperature: decreases glue viscosity
Initial: 165°C
Recommended: 160 °C to 170 °C
Do not make unnecessary change in the temperature setting of sensors inside the melt tank.
Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.
Press [Finisher Adjustment], [Perfect Binder Adjustment], and [Temperature Adjustment] in sequence.
Load cover paper in either Perfect Binder Cover Tray or any other tray.
Load paper for body sets in the desired tray.
Press the key of the item to be adjusted.
Press [Print Mode].
Select the tray loaded with paper for body sets.
Press Start on the control panel.
A sample pattern of perfect-bound book is printed.
Check that the glue applied on the body set is in proper condition.
If any adjustment is required, press [Exit PrintMode] to return to the [Temperature Adjustment] screen.
Use the touch panel keypad to enter the set value.
Use [+/-] to specify the value to be positive or negative; since this adjustment item is for setting the temperature, the final value cannot be set to be negative.
Press [Set] to change the current value.
Repeat steps 6 to 11 until the desired result is obtained.
Press [Return].