Adjust the magnification in paper feed direction in the printer engine. This adjustment value will be the standard for Both Sides Adjust in Paper Setting.
Objects of Adjustment: Printer FD-Mag., Tray 1 Offset (ADU) to Tray 9 Offset (ADU)
Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.
Press [Machine Adjustment], [Printer Adjustment], and [FD-Mag. Adjustment] in sequence.
Press the key of the object to be adjusted.
Press [Print Mode].
Load A3 paper into the tray to be adjusted, then select that tray.
Press Start on the control panel.
A sample pattern will be output.
Measure the resultant magnification in the paper feed direction.
Allowance: ± 0.5% or less (full size)
Within 205.7 mm ± 1 mm
If any adjustment is required, press [Exit PrintMode] to return to the [FD-Mag. Adjustment] screen.
Use the touch panel keypad or the keypad on the control panel to enter the setting data.
Use [+/-] to specify the value to be positive or negative.
Press [Set] to change the current value.
Adjustment Range:
- [Printer FD Mag.]: -100 ([Short]) to +100 ([Long]) (1 step = 0.01%)
- [Tray 1 Offset (ADU)] to [Tray 9 Offset (ADU)]: -80 ([Short]) to +20 ([Long]) (1 step = 0.01%)
Repeat steps 4 to 9 until the desired result is obtained.
Press [Return].