* Enter the name of the utility key. You can search descriptions of utility keys.
Gradation Adjustment
To display: [Utility][Administrator Settings][System Settings][Expert Adjustment][Gradation Adjustment]
Restart this machine.
Check that [Image Stabilization Only] is selected in [Expert Adjustment] - [Gradation Adjustment] and then press the Start key.
The image stabilization operation starts. Now adjustment items on the right are available for selection.
Select items to be adjusted.
[Printer (600dpi)]: Select this option when the image printed with resolution 600dpi has irregular gradation.
[Print (1200dpi)]: Select this option when the image printed with resolution 1200dpi has irregular gradation.
[Copy]: Select this option when a copied image has irregular gradation.
Select a paper type for printing a test pattern.
Bypass Tray cannot be selected.
Press the Start key.
A test pattern is printed.
Place the test pattern on the Original Glass in the orientation indicated on the Touch Panel.
Place ten or more blank sheets of paper to prevent bleeding of the test pattern.
Close the ADF or Original Cover.
Press the Start key.
The test pattern is scanned and the gradation level is automatically adjusted.
Repeat steps 3 to 9 twice. (Total of three times)