Recovering this machine from ErP Auto Power Off mode

Configure the setting to recover the machine from the ErP Auto Power Off mode via the network when the machine is connected to a mobile terminal.

Select [Network] - [Awake from ErP] in administrator mode of Web Connection (or in [Utility] - [Administrator] of this machine), and configure the following settings.

Setting

Description

[Awake from ErP]

Select the method to return the machine from the ErP Auto Power Off mode (default: [Awake with Magic Packet]).

  • [Awake with Magic Packet]: The machine returns from the ErP Auto Power Off mode when receiving a magic packet.

  • [Awake with ARP + Unicast Communication]: The machine returns from the ErP Auto Power Off mode when receiving a unicast communication packet.

Tips
  • This function is not available when the machine is used in the IPv6 environment.

  • This function is not available when [Network] - [Network I/F Configuration] is set to [Wireless Only].

  • To recover the machine from the ErP Auto Power Off mode using bizhub Remote Access on a mobile terminal, connect this machine to the mobile terminal once in advance.