Home Settings and AdjustmentsCD-Mag. Adjustment: Adjusting the Magnification in Crosswise Direction in the Printer

CD-Mag. Adjustment: Adjusting the Magnification in Crosswise Direction in the Printer

Adjust the magnification in crosswise direction in the printer engine.

Objects of Adjustment: Printer CD-Mag., Tray 1 Offset (ADU) to Tray 9 Offset (ADU)

  1. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen.

  2. Press [Machine Adjustment], [Printer Adjustment], and [CD-Mag. Adjustment] in sequence.

  3. Press the key of the object to be adjusted.

  4. Press [Print Mode].

  5. Load A3 paper into the tray to be adjusted, then select that tray.

  6. Press Start on the control panel.

    A sample pattern will be output.

  7. Measure the resultant magnification in the direction perpendicular to the paper feed direction.

    Allowance: ± 0.5% or less

    Within 190 mm ± 1 mm

  8. If any adjustment is required, press [Exit PrintMode] to return to the [CD-Mag. Adjustment] screen.

  9. Use the touch panel keypad or the keypad on the control panel to enter the setting data.

    • Use [+/-] to specify the value to be positive or negative.

    • Press [Set] to change the current value.

    • Adjustment Range: -100 ([Short]) to +100 ([Long]) (1 step = 0.01%)

  10. Repeat steps 4 to 9 until the desired result is obtained.

  11. Press [Return].

    The screen returns to the [Printer Adjustment Menu] screen.